5.
Select item 1 named CCD calibration used Mode dial. Item number is shown on a status LCD.
"Manual Rec" mode shown as items 1 on B/W LCD.
6.
Press shutter to run CCD Calibration Test
7.
If Color LCD display "** OK **", Camera Passes Record Data to Traveler Sheet and Pass to next station.
If Color LCD display "** Error ???**", Camera Fails, record failure code and submit to Failure Analysis.