Enclosure Cover - Graco Ultra QuickShot 20B473 Repair Manual

Hide thumbs Also See for Ultra QuickShot 20B473:
Table of Contents

Advertisement

Enclosure Cover Removal
NOTICE
Do not use a power drill on the sprayer.
Doing so can cause damage to the
threads.
1.
Perform Pressure Relief Procedure,
page 4.
2.
Remove battery (24) from sprayer.
3.
Remove cup assembly (10).
4.
Turn prime knob (12) forward to spray
position.
5.
Remove cross-head screw (21) from
prime knob (12) and remove knob.
6.
Remove five cross-head screws (20)
from sprayer enclosure and remove

enclosure cover (18).

3A9322B
Enclosure Cover
Replacement
1.
Before installing enclosure cover,
ensure wires are laid securely in wire
channels, away from pinch points such
as screw bosses and between the
enclosure seam.
NOTICE
Failure to ensure wires are away from
pinch points could cause the sprayer to
become inoperable after assembled.
Route the wires exactly as shown below.
2.
Install new enclosure cover (18). Secure
with five cross-head screws (20). See
Assembly Drawing, page 2, for
torques.
3.
Rotate prime valve stem so the valve
stem cross hole is oriented front to back
along the length of the sprayer.
5

Advertisement

Table of Contents
loading

Table of Contents