5. SETUP INSTRUCTIONS

Refer to Figure 3.0
NOTE: This installation uses luer lock adapters shipped with the valve. Any approved material
line with 1/8" NPT connections will work.
1. If desired, mount the valve to the bracket included (1).
2. Connect fluid feed line to valve inlet port (2).
3. Insert the open end of the air hose to air inlet fitting (3) then connect the other end to an
approved valve controller.
4. Set the fluid reservoir pressure. Do not exceed 100 psi (6.9 bars)
5. Install desired dispense tip (4) to the valve outlet and secure it with the retaining ring (5)
NOTE: Recommended dispense tip size is 22-gauge or smaller. Use larger than 22-gauge
dispense tip may results in valve leakage.
6. Make sure all connections are tight
7. Place container under the valve outlet and activate the valve until the fluid flows steady.
The amount of fluid that flows through the valve is determined by:
• Flow control adjustment - Turn end cap counterclockwise to increase material flow rate.
• Length of actuation, set at controller (Valve open time).
• Fluid reservoir pressure
• Dispensing tip size