Page 1
Cont ntr r ol oll l er er For: Ration Belt Weighfeeder For: Ration Belt Weighfeeder Operatio Operation n Ma Manu nual V3 al V3.6 .6 Changsha Supmeter T Changsha Supmeter Technol echnol ogi ogi cal Co., cal Co.,Ltd. Ltd.
Page 2
Preface Preface Thank you very much for your purchase! Thank you very much for your purchase! This manual covers safety precaution, technical specification, operation interface, installation& This manual covers safety precaution, technical specification, operation interface, installation& connection, function&operation and so on. In order to make the product running at its best, please read this connection, function&operation and so on.
Page 3
Contents Contents 1. SAFETY PRECAUTION 1. SAFETY PRECAUTION ......................................4 ..........4 2. 2. TECHNICAL SPECIFIC TECHNICAL SPECIFICA A TION ............... TION ....................5 ......5 3. 3. OPERA OPERATION INTERF TION INTERFACE ......ACE ......................................7 3.1 M M ............
6.3.1 Basic Scale Parameters ......................28 6.3.2 Extra Scale Parameters ......................29 6.3.3 Basic Control Parameters ......................30 6.3.4 Extra Control Parameters ......................31 6.3.5 Flow Parameters ........................32 6.3.6 Speed Parameters ........................33 6.3.7 Load Parameters ........................34 6.3.8 Weight Record Parameters ......................
Page 5
1. Safety Precaution Lithiu m Battery Installation A Lithium battery should be equipped in the product. If it is not allowed to be transported together with the product because of embargo, please make a purchase according to the model offered by us and install it by yourself. Prohibit using th e product under dangerous environment ...
Page 6
2. Technical Specification Executing Standard 《 》 CMC GB/T 7724-2008 Electronic Weighing Meter PRC National Standard. 《 》 OMIL R50:1997 Continuous Totalizing Automatic Weighing Instruments International Recommendation. Accuracy Grade: 0.5. Display 128×64 LCD display screen with 7 background colors for English/Chinese display. ...
Page 8
4.2 Terminal 4.2.1 Model Horizontal Panel-mounting Terminal A A A A A A A A V P C O O O O O O I I I O O O O O O O O O O I I I + ...
Page 9
4.2.3 Model Vertical Panel-mounting Terminal R E W O P DO4- I D / DO4+ O DO3- D DO3+ DO2- DO2+ DO1- DO1+ T E N EXC+ R E EXC- H T E SIG+ R SIG- O S SEN- N AI- E O...
Page 10
No. Description SENSOR Loadcell / Speed Sensor Port LOADCELL Loadcell 4-Wire Connection Mode 6-Wire [Default Set] SEN+ Feedback Voltage +. SEN- Feedback Voltage -. SIG- Weighing Signal [mV]Input -. Weighing Signal [mV]Input -. SIG+ Weighing Signal [mV]Input +. Weighing Signal [mV]Input +. EXC- Excitation Voltage -.
6.4 F2 System Calibration 6.4 F2 System Calibration 6.4.1 Zero Calibration 6.4.1 Zero Calibration Keep the belt weigher running without load Keep the belt weigher running without load for correcting Zero for correcting Zero V V alue. alue. Main Display Interface Main Display Interface 【...
6.4.2 Dynamic Span 6.4.2 Dynamic Span Calibration Calibration Let the belt weigher run with loading measured materials or Poise Weights for correcting Span Let the belt weigher run with loading measured materials or Poise Weights for correcting Span Coefficient. Coefficient. Main Display Interface Main Display Interface 【...
【 】 2 Span Cal. Dyn. OldSpan: 200000 NewSpan: 200320 E% = (Display Weight – Input Weight) / Input Weight × 100% -0.16% 【 】 【 】 MENU : Exit : Save 6.4.3 Static Span Calibration with Chain Weight Keep the belt weigher running with loading a chain weight for correcting Span Coefficient. Put a measured chain weight as a continuous and steady load on the belt weigher and then start the belt weigher.
Page 18
【 】 3 Span Cal.Stat1 1.0kg 【 】 【 】 ▲ ▼ Load: 9.98kg/m Display Flow, Load , AD Value 10.00m Remainder length of a revolution Revolution Count After running Calibration Revolutions: 3 Span Cal.Stat1 499.2kg [ENT]: Input… 【 】 Input Weight Input Calibrating Weight = Cal.
6.4.4 Static Span Calibration with Hanging Weight Keep the belt weigher running with loading hanging weights for correcting Span Coefficient. Put a measured hanging weight as a steady load on the belt weigher and then start belt weigher. Main Display Interface 【...
6.4.7 Belt Length Calibration Keep the belt weigher running at a constant speed. After the belt running time of a revolution being measured by stopwatch, do this operation for correcting Belt Length. Main Display Interface 【 】 【 】 【 】...
6.5 F3 Weight Record for Querying&Printing Weight records per shift/day/month of a year can be queried and printed. Main Display Interface 【 】 【 】 【 】 MENU ▲ ▼ : F3 Weight Record 【 】 F3 Weight Record - -...
Need help?
Do you have a question about the BST100-E11 and is the answer not in the manual?