Basics - Bartec VOLUTANK PETRO 3003 Operating Instructions Manual

Incl. safe+spds
Hide thumbs Also See for VOLUTANK PETRO 3003:
Table of Contents

Advertisement

Basics

6
3
„VOLUTANK 3003":
„SAFE 3003"
„SPDS 3003":
Wet hose delivery 3003
TIGER Ex
Fuel tanker Combo
GPRS/UMTS-online function
GPS petrol station database
Shift matrix
Simultan delivery G+P
Product selection delivery
TVE1 – TVE2 communication
SPD minitrailer
SPDS 3003 Stand alone
SAFE 3003 Stand alone
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020))
Basics
The PETRO 3003 system can be used to monitor, record and control all op-
erations and operating processes for loading and unloading petroleum vehi-
cles. The system is extremely flexible and can be adapted to meet different
requirements using the variable range of hardware components.
Software options
For the software from version pyramid 2.5.X, various options are only availa-
ble after purchasing a corresponding license.
When updating from an older software version without options which require
a license, all options used up to that point remain active.
Basic options
Electronic dipsticks are used in the measuring system to record the quantities
when the products are loaded or delivered.
The quality assurance system prevents products from being mixed during
loading or delivery (section 4.2.8, 4.3.4.3, 6.6 and 6.7).
The Sealed Parcel Delivery System is used to seal loads electronically on pe-
troleum vehicles. This ensures that the product arrives at the customer's prem-
ises in the same quantity and quality that was present during loading (section
4.4).
Further options for the operation of the measuring system, which can be
combined with the basic functions
Dipstick volume measurement with wet hose delivery
Measuring system TIGER Ex, Turbine measuring system. (The system is
operated like the delivery described via the collector.)
Dipstick rigid & trailer with automatic control,
pumped delivery from the trailer over the rigid.
A separate quick guide is provided for this.
Office connection, reading out data and data specification TVE1
Automatic localization of the petrol stations via GPS and display of the as-
sociated customer data.
Company-specific requirement for the deliveries / bypasses
Simultaneous delivery via direct outflow and collector delivery
Product selection for collector delivery with additive pump
TVE1 TVE2 shared printer, office connection TVE2.
Single compartment trailer, only possible in connection with rigid with option
SPDS 3003, no quantity measurement.
Electronic sealing of the cargo, Valve monitoring with recording;
no quantity measurement.
Quality assurance system to prevent product mixing during loading and de-
livering; no quantity measurement.
The content of the displays depends on the software options installed, their
configuration and the hardware components used. Depending on this, the dis-
play images shown in this document may differ from those on your system.
(see section 4.5)
(see section 4.2.6 and 6.9)
(see section 6.7)

Advertisement

Table of Contents
loading

This manual is also suitable for:

308981314101

Table of Contents