Replacing batteries

Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes and
may be extremely toxic.
Determine if the battery is inadvertently grounded. If inadvertently grounded, remove source from ground.
Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can
be reduced if such grounds are removed during installation and maintenance (applicable to equipment and
remote battery supplies not having a grounded supply circuit).
ELECTRIC ENERGY HAZARD. Do not attempt to alter any battery wiring or connectors. Attempting to alter
wiring can cause injury.
Disconnect charging source prior to connecting or disconnecting battery terminals.
Replacing the internal battery
The internal battery is heavy. Use caution when handling the heavy batteries.
Figure 17. Internal Battery Pack Replacement
To replace the battery pack:
1.
Remove the center cover of the front panel.
2.
Push left cover toward to right direction.
3.
Open the battery door.
4.
Disconnect the battery connectors.
A ribbon cable connects the LCD control panel to the UPS. Do not pull on the cable or disconnect it.
34
Tripp Lite by Eaton SmartOnline Series User Guide 614-21325—Rev 01
2
1
6
3
4
5