Current consumption:
Note:
1. When measuring these current, it is recommended to use the analog ammeter to make the
measurement easier due to protecting the ammeter from noises.
2. Make LCD display contrast suitable (default) condition before measurement.
3. Measure under the ambient temperature range 15˚C~35˚C
Operation Mode
Main Menu of OPERATION
CHECK in this manual
* POWER CONTROL of
OPERATION CHECK
* POWER CONTROL of
OPERATION CHECK
Power/OFF
Power/OFF
*Tapping 5 POWER CONTROL in the OPERATION CHECK Main Menu screen display, the following
display will appear.
Currently CPU clock :
VT Clock :
Push Action key to exit
Voltage detection:
Main (Rechargeable) Battery:
VDET2 : approximately 3.1 V (Forced power OFF)
Back-up Battery:
VDETS : approximately 2.8 V (Low battery message)
Unit Alignment Condition for data transfer using IrDA :
Length (L)
Angle (A)
L ≤ 30 cm
Input Voltage
Rechargeable Battery :
4.0 ± 0.1V
Rechargeable Battery :
4.0 ± 0.1V
AC Adapter : 5.9V ± 0.1V
Rechargeable Battery :
4.0 ± 0.1V
Lithium battery for back-up
3.0 ± 0.1V
150 MHz
50 MHz
A ≤ 15˚
EG-800
— 3 —
Current Consumption
≤180mA
≤370mA
≤370mA
≤2.5mA
≤1.9mA