Panasonic WJ-MPU955 User Manual page 141

Admin console
Hide thumbs Also See for WJ-MPU955:
Table of Contents

Advertisement

Appendix A
S P E C I F I C N O T I F I C A T I O N
F i e l d D a t a
Alarm UDP IP
Description: Specifies a destination IP address for TCP alarm notification. This setting is
address
effective only when Alarm UDP Destination is 1.
Validation: Dotted decimal format IP address - 0.0.0.0 to 255.255.255.255
Default Setting: (None)
Description: Specifies a destination IP port for TCP alarm notification. This setting is effective
Alarm UDP Port
only when Alarm UDP Destination is 1.
No.
Validation: hexadecimal numeral 0000 -FFFF
Default Setting: (None)
Description: Specifies a retry timer for an alarm notification. When device does not receive a
Alarm
response of an alarm notification packet, it sends the same packet after this timer expires.
Retransmission
Timer
Validation: decimal numeral 0-255
Default Setting: (None)
Comment Description: A string to put comment notes.
Validation: Within 16 characters.
Default Setting: (None)
137