CONDITIONING PLANTS
E.- The unit is linked to the electrical connections box
with a 1 m long cable. So around the unit (compres-
sor assy for Split models) there should be enough
space for the box installation in a way to easy electri-
cal connections and maintenance.
F.- The thermostat bulb and the air filter shall be
installed on the refrigerant-ambient air heat exchang-
er (evaporator). It is necessary to leave enough
space at the side of the unit for periodical mainte-
nance.
G.- The maximum distance between unit and control
panel is 3 m both for the thermostat capillary and for
the connecting cable.
2.3 - INSTALLATION
The air-conditioner shall be installed using the stain-
less steel brackets supplied with it. It is better to use
a silent block mounting, if you install the compressor
in a cabin. It is also important not to force on the
cable linking the unit to the connection box.

2.4 - CONDENSATE DRAIN

The condensate discharge hose
should be connected to the 19 mm
drain nipples of the pans.
2.6 - BULB THERMOSTAT - C318
The thermostat bulb should be fastened to the refrigerant-ambient air heat
exchanger by means of two plastic fasteners. The bulb shall not touch the heat
exchanger fins as the direct contact will influence the thermostat set. The ther-
mostat feels only the return air. In particular situations it is possible to install the
bulb not directly on the exchanger, but in the room to feel its temperature using
the plastic plate supplied with the control panel.
page 5
SPLIT and COMPACT models
2 COMPONENTS INSTALLATION

2.5 - SEA WATER CIRCUIT

The refrigerant -
sea water heat
exchanger has
two 16 mm hose
fittings to be con-
nected to the
water circuit by
means of an
adequate rubber
or plastic hose. The flow sense is marked with arrows; anyhow the water
enters from the bottom coil of the heat exchanger and goes out from the top
outlet. Hose routing should avoid siphoning which will prevent the pump to
prime. The over board outlet port should be as low as possible but above the
water line: this to limit the water discharge noise and to avoid horizontal jets.
Unità
acqua
SPLIT 4
SPLIT 8
mod.
Mod.
COMPACT 5
COMPACT 9
Ac. L/m
L/m'
7
SPLIT 10
SPLIT 16
COPMACT 12
COPMACT 17
8
10
Neoprene
SPLIT 17 slim
COPMACT 17 slim
15
15
www.climma.it
SPLIT 22 slim
COPMACT 24 slim
15
20