2.12- PRECHARGED CONNECTIONS WITH QUICK CONNECTS
Air-conditioner models Split 4-6-8 are composed by two parts: compressor assembly and evaporator both EV
and FC models. The refrigerant circuit is done by means of precharged copper lines equipped with quick con-
nects for easy installation. The standard length of piping is 70 cm, connected to the evaporator side. If extra-
length is needed to move away the two parts, precharged extensions are available on request. When con-
necting the pipes, make sure to follow the indications "Compressor side" and "Evaporator side" as shown
below. Handle and bend carefully the pipes to avoid any breakage because of wrong use. The minimum bend-
ing radius is 50 mm.

CONNECTING LINES

2.13 -
FOR SPLIT 10,14 AND 16
These units are not supplied precharged. The con-
nection between the two parts is "flare" type. It is
therefore necessary the intervention of a refrigeration
engineer for evacuating the system and filling it with
the adequate refrigerant charge. The unit copper
connecting lines must have the following minimum
diameter:
page 10
SPLIT and COMPACT models
2 COMPONENTS INSTALLATION
(only for Split models) -C300