Download Print this page
FlowLine MicroPoint LI42 Series Owner's Manual

FlowLine MicroPoint LI42 Series Owner's Manual

Multi-channel indicator with alarms

Advertisement

Quick Links

Spec Tech Industrial Electric
Warranty, Service & Repair
To register your product with the manufacturer, go to the Flowline
website for on-line registration. The website address is as follows:
www.flowline.com
On-line Warranty Registration can be found under Contact Us in
the Navigation Bar along the side of the home page.
If for some reason your product must be returned for factory ser-
vice, contact Flowline Inc. at (562)598-3015 to receive a Material
Return Authorization number (MRA), providing the following
information:
1. Part Number, Serial Number
2. Name and telephone number of someone who can answer
technical questions related to the product and its application.
3. Return Shipping Address
4. Brief Description of the Symptom
5. Brief Description of the Application
Once you have received a Material Return Authorization number,
ship the product prepaid in its original packing to:
Flowline Factory Service
MRA _____
10500 Humbolt Street
Los Alamitos, CA 90720
To avoid delays in processing your repair, write the MRA on the
shipping label. Please include the information about the malfunc-
tion with your product. This information enables our service tech-
nicians to process your repair order as quickly as possible.
WARRANTY
Flowline warrants to the original purchaser of its products that such
products will be free from defects in material and workmanship under
normal use and service for a period which is equal to the shorter of
one year from the date of purchase of such products or two years from
the date of manufacture of such products.
This warranty covers only those components of the products which
are non-moving and not subject to normal wear. Moreover, products
which are modified or altered, and electrical cables which are cut to
length during installation are not covered by this warranty.
FLOWLINE's obligation under this warranty is solely and exclusively
limited to the repair or replacement, at FLOWLINE's option, of the prod-
ucts (or components thereof) which FLOWLINE's examination proves
to its satisfaction to be defective. FLOWLINE SHALL HAVE NO
OBLIGATION FOR CONSEQUENTIAL DAMAGES TO PERSON-
AL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON.
This warranty does not apply to products which have been subject to
electrical or chemical damage due to improper use, accident, negli-
gence, abuse or misuse. Abuse shall be assumed when indicated by
electrical damage to relays, reed switches or other components. The
warranty does not apply to products which are damaged during ship-
ment back to FLOWLINE's factory or designated service center or are
returned without the original casing on the products. Moreover, this
warranty becomes immediately null and void if anyone other than ser-
vice personnel authorized by Flowline attempts to repair the defective
products.
Spec Tech Industrial Electric
www.spectechind.com
MicroPoint™
Indicator with Alarms
LI42 Series (2-Channel)
Owner's Manual
IP
65
Version 2.1A
© 2004 FLOWLINE Inc.
All rights reserved.
Manual # LI900004 - 0410-LI42M2_1
Products which are thought to be defective must be shipped prepaid
and insured to FLOWLINE's factory or a designated service center
(the identity and address of which will be provided upon request)
within 30 days of the discovery of the defect. Such defective products
must be accompanied by proof of the date of purchase.
Flowline further reserves the right to unilaterally waive this warranty
and to dispose of any product returned to Flowline where:
a. There is evidence of a potentially hazardous material present
with product.
b. The product has remained unclaimed at Flowline for longer than
30 days after dutifully requesting disposition of the product.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND
THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This
warranty and the obligations and liabilities of Flowline under it are
exclusive and instead of, and the original purchaser hereby waives, all
other remedies, warranties, guarantees or liabilities, express or
implied. EXCLUDED FROM THIS WARRANTY IS THE IMPLIED
WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTIC-
ULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF
MERCHANT ABILITY OF THE PRODUCTS.
This warranty may not be extended, altered or varied except by a writ-
ten instrument signed by a duly-authorized officer of Flowline, Inc.
www.spectechind.com
888-773-2832
®
Multi-Channel
888-773-2832

Advertisement

loading
Need help?

Need help?

Do you have a question about the MicroPoint LI42 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for FlowLine MicroPoint LI42 Series

  • Page 1 FLOWLINE's obligation under this warranty is solely and exclusively 30 days after dutifully requesting disposition of the product. limited to the repair or replacement, at FLOWLINE's option, of the prod- ucts (or components thereof) which FLOWLINE's examination proves THERE ARE NO WARRANTIES WHICH EXTEND BEYOND to its satisfaction to be defective.
  • Page 2: Specifications

    Spec Tech Industrial Electric www.spectechind.com 888-773-2832 SPECIFICATIONS Step One LI42-1001 Display type: LCD, 5-digit Indicator Front View Display units: Factory cal: % of span PC cal: engineering* 3.12" Decimal point: Floating (79.2 mm) Display output: Transmitter: 0-99999 Switch: Good / alarm* Display height: 0.4"...
  • Page 3 LI42-1001 Multi-channel level active channels. The compact NEMA 4X enclosure supports indicator from FLOWLINE. Please refer to the part number locat- panel and wall mount installations. ed on the indicator label to verify the exact model configuration which you have purchased.
  • Page 4 Purple: Chan-2 FET switch 20 mA = 100.0% C. Sensor Cable: The maximum cable distance between the indicator and attached Flowline transmitter, level or leak detec- Display decimal point: 1-place (100.0%) tion switch is 1000 feet (304m). Use a well insulated and shield-...
  • Page 5: Installation

    Spec Tech Industrial Electric www.spectechind.com 888-773-2832 INSTALLATION WIRING Step Six Step Seven A. Wiring the LI42-1001 to (1) Level Transmitter and (1) A. Introduction: The NEMA 4X indicator is designed to sup- Alarm (Note: Alarm Functions Require MicroCal Calibration) port both panel and wall mount installations. Panel mount installations are generally used when the indicator is remote from the tank(s) and placed in a consolidated instrument panel.
  • Page 6: Troubleshooting

    Spec Tech Industrial Electric www.spectechind.com 888-773-2832 WIRING TROUBLESHOOTING Step Seven Step Eight C. Wiring the LI42-1001 to (1) Level Transmitter, (1) Level A. Display Descriptors: The following are the display’s opera- Switch (2) Alarms and (1) PLC (Note: Switch and Alarm tional descriptors, meaning and corrective action: Functions Require MicroCal Calibration) CH=_...

This manual is also suitable for:

Micropoint li42-1001Micropoint li44-1001Micropoint li44 series