Download Print this page

Flame Failure Safety Feature - Fisher & Paykel OR60SDBSX2 Using Manual

Hide thumbs Also See for OR60SDBSX2:

Advertisement

• Turn the power to the cooker on at the wall.
• Make sure all controls are turned off.
Using the gas burners
1. Choose the control knob for the burner you want to use.
2. Press the knob down gently and turn it anticlockwise to the
position. The ignitors on all the burners will spark.
3. Hold down the knob for approximately 10 seconds after the burner has lit. Releasing the knob too soon will
extinguish the flame.
4. Adjust the flame anywhere between the
and
positions. Do not adjust the flame between
0
and
(OFF).
If the burner does not light within 15 seconds, turn the control knob off and wait at least one
minute before trying again.
5. To turn the burner off, turn the knob clockwise to
the knobs to the

Flame failure safety feature

• The flame failure probe cuts off the gas supply to the burner if the flame is blown out.
• When lighting the burner on flame failure models, hold down the knob for approximately 10 seconds after the
burner has lit. Releasing the knob too soon will extinguish the flame.
• If the flames are accidentally extinguished, turn off the burner and do not try to light it again for at least one
minute (to allow the gas to disperse).
https://producthelp.fisherpaykel.com/au/Cook/Freestanding_Cookers/Electric/OR60SDBSX2/User_Guide_OR60SDBSX2_(59...
0
(OFF) position.
0
(OFF) until you hear the safety click. After use, always turn
Updated: Mon, 20 Mar 2023 17:44:50 GMT
Powered by
3

Advertisement

loading