Assemblers and other persons who are not employed by or otherwise directly affiliated with or autho- rized by Siemens or one of its affiliates are directed to contact one of the local offices of Siemens or one of its affiliates before attempting installation or service procedures.
FLUOROSPOT Compact imaging system ..... . . 2 - 5 UROSKOP Access basic system ......2 - 5 Multileaf collimator.
Page 4
0 - 4 Contents Page UROSKOP ACCESS SPL5-330.861.01 Page 4 of 4 Siemens AG System Rev. 02 04.05 CS PS 24 Medical Solutions...
Page 5
NOTICE All drawings and pictures in this document relate to the left-hand version of the system. NOTE This document relates to UROSKOP Access both with ASPIA imaging system and FLUOROSPOT Compact imaging system. Siemens AG SPL5-330.861.01 Page 1 of 4...
1 - 2 General System overview ASPIA imaging system FLUOROSPOT Compact imaging system Fig. 1 UROSKOP ACCESS SPL5-330.861.01 Page 2 of 4 Siemens AG System Rev. 02 04.05 CS PS 24 Medical Solutions...
General 1 - 3 List of pollutants Depending on the system version supplied, the following components of the UROSKOP Access require special disposal: Component Pollutant Quantity 1/Fig. 1 TFT support arm n.a. n.a. 2/Fig. 1 X-ray tube assembly metallic lead 2.0 kg...
Page 8
1 - 4 General This page intentionally left blank. UROSKOP ACCESS SPL5-330.861.01 Page 4 of 4 Siemens AG System Rev. 02 04.05 CS PS 24 Medical Solutions...
If not observed, death, serious physical injury or damage to prop- erty can occur. Observe - the general safety information of document TD00-000.860.01) and - the safety information according to ARTD 2. Siemens AG SPL5-330.861.01 Page 1 of 8 UROSKOP ACCESS Medical Solutions Rev. 02 04.05 CS PS 24 System...
If not observed, death or serious physical injury can occur. The system can be contaminated with infected blood or other body fluids. Work strictly according to the safety guideline ARTD-002.731.37. UROSKOP ACCESS SPL5-330.861.01 Page 2 of 8 Siemens AG System Rev.
Move the tube support arm all the way to the foot end. • Move the tabletop flush. • Switch the system "off". Fig. 1 Siemens AG SPL5-330.861.01 Page 3 of 8 UROSKOP ACCESS Medical Solutions Rev. 02 04.05 CS PS 24 System...
• Remove the cover of the PCs on the left side of the ASPIA container (Fig. 2). • Dispose of the coin cell on the motherboard (1/Fig. 2); lithium battery. UROSKOP ACCESS SPL5-330.861.01 Page 4 of 8 Siemens AG System Rev.
Remove the cover panel on the left side of the FLUOROSPOT Compact container (Fig. 3). • Dispose of the coin cell on the mother board (1/Fig. 3); lithium battery. UROSKOP Access basic system 1/Fig. 4 Multileaf collimator, basic unit lead 2/Fig.
Page 14
2 - 6 Disassembly and Disposal Fig. 4 UROSKOP ACCESS SPL5-330.861.01 Page 6 of 8 Siemens AG System Rev. 02 04.05 CS PS 24 Medical Solutions...
The tube assembly must be returned to the following address for disposal: SIEMENS AG Medical Solutions Rückwarenabteilung Strahler Henkestrasse 127 D-91052 Erlangen Siemens AG SPL5-330.861.01 Page 7 of 8 UROSKOP ACCESS Medical Solutions Rev. 02 04.05 CS PS 24 System...
• Substances at the output screen (3/Fig. 7) phosphorus NP 1043 lead-containing solders silicone sealing compound • Substances at the ceramics part (4/Fig. 7) UROSKOP ACCESS SPL5-330.861.01 Page 8 of 8 Siemens AG System Rev. 02 04.05 CS PS 24...
Page 17
First note new; in subchapter "List of pollutants" FLUOROSPOT Compact added Chapter 2 Subchapter "Safety Information" revised; new subchapter "FLUOROSPOT Compact Imaging system" Tab. 1 Siemens AG SPL5-330.861.01 Page 1 of 2 UROSKOP ACCESS Medical Solutions Rev. 02 04.05 CS PS 24 System...
Page 18
3 - 2 Changes to previous version This page intentionally left blank. UROSKOP ACCESS SPL5-330.861.01 Page 2 of 2 Siemens AG System Rev. 02 04.05 CS PS 24 Medical Solutions...