Kyocera FS-1100 Service Manual page 73

Hide thumbs Also See for FS-1100:
Table of Contents

Advertisement

7. Remove five screws and then remove the
control PWB.
8. Check or replace the control PWB and refit
all the removed parts.
To replace the control PWB, remove the
EEPROM (U300) from the old control PWB
and mount it to the new control PWB.
All manuals and user guides at all-guides.com
EEPROM
Screw
Screw
Control PWB
U300
Control PWB
Figure 1-5-29
2H5/2HS
Screw
Screw
Screw
1-5-21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1300d

Table of Contents