PUTTING INTO OPERATION

Check that the voltage on the identification plate is the same as that of the network.
THE ELECTRICAL SUPPLY LINE TO WHICH THE HOT CASE WILL HAVE TO BE CONNECTED IS
TO BE PROTECTED BY a Residual Current Circuit Breaker with Overload Protection (Rated
current = 32A, rated residual operating current = 30mA); IT IS ALSO TO BE LINKED TO THE
GENERAL EARTHING PLANT.
The manufacturer disclaims all responsibility for any damage to people or things due to incorrect
observance of this rule. Earthing is necessary and compulsory by law. Absolutely never use
reduction units, patch cords, adapters or multiple socket outlets to connect the counter.
DIRECTLY connect the equipment to the mains.
Disconnection from the supply mains having a contact separation in all poles that provide full
disconnection and must be incorporated in the fixed wiring in accordance with the wiring rules
FOR OFFLIP HOT 70, 93 and 125
Power input Connection, Cabinet is Appliance with Fix Wiring type. So, it must be connected power in
by professionally qualified personnel with wiring type H05VV-F size 4 sq. mm. at least directly to
Cabinet Circuit Breaker as the connection process according to the diagram.
32A
IMPORTANT: THE EQUIPMENT MUST BE PROPERLY EARTHED. The manufacturer assumes no
responsibility for any damage resulting from non-observance of this safety principle. If the cabinet
must be installed far from electric power source, make certain that the connection complies with the
standards in force.