Horizontal Exhaust Through Wall Installation - HAMPTON BAY Greenfire GC60-2 Technical Manual

Freestanding cast iron pellet stove
Hide thumbs Also See for Greenfire GC60-2:
Table of Contents

Advertisement

h
e
orizontal
xhauSt
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces,
or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and
Equipment and with all local regulations, including those referring to regional and national. Only use
venting of L or PL type or corn certified venting if corn will be burned as a fuel with an inside diameter of 4
inches (100 mm). All joints in the exhaust venting system must be fastened with at least three (3) screws.
1. Place the appliance 15" (37.5 cm) away from the wall. If the stove will be installed on a hearth pad,
set the unit on it.
2. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located
the center point on the wall, refer to pellet vent manufacturer installation instructions for correct hole
size and clearance to combustibles.
3. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour
barrier in accordance with local building codes.
4. Install a length of vent pipe into the wall thimble. Try not to have joints inside the thimble. The pipe
should install easily into the thimble.
5. Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal the connection with high
temperature silicone.
6. Install the fresh air intake (see O
7. Push the stove straight back, leaving a minimum of 3" (7.6 cm) clearance from the back of the stove
to the wall. Refer to Vent Manufacturers' instructions if sealant is required.
3"(80mm) Intake
4"(100mm) Pellet Vent Wall Thimble
14
Installation
t
W
i
hrough
all
nStallation
F
utside
resh
GC60
GC60-2
Figure 11: Straight through wall Installation.
:
A
C
).
ir
OnneCtiOn
REFER TO VENT MANUFACTURER'S INSTRUCTIONS
FOR CLEARANCES AND SEALING REQUIREMENTS.
4"(100mm) Exhaust
4"(100mm) Pellet Vent Pipe
Hampton GC60-2 Cast Pellet Stove Technical Manual
45 Elbow with
Screen or
Termination Cap

Advertisement

Table of Contents
loading

Table of Contents