1 Technical Specification

Dimensions
1.1
Diameter:
Length:
Construction
1.2
Body:
Faceplate:
Penetration of Field
1.3
Approximately 75 -100mm dependent upon material
Range of Moisture
1.4
For bulk materials the sensor will measure up to the point of saturation.
Operating Temperature Range
1.5
0-60°C (32-140°F).The sensor will not measure in frozen material
Power Supply Voltage
1.6
15 - 30 VDC. 1 A minimum required for start-up (normal operating power is 4W).
Analogue Output
1.7
Two configurable 0–20mA or 4-20mA current loop outputs (sink) available for moisture and
temperature. The sensor outputs may also be converted to 0-10Vdc
Measurement Modes
1.8
1.8.1
Hydro-Probe
Mode F only
1.8.2
Hydro-Probe XT
Mode F, Mode E, Mode V
Brix measurement output
1.9
No
Digital (Serial) Communications
1.10
Opto-isolated RS485 2 wire port – for serial communications including changing operating
parameters and sensor diagnostics.