Radleys Carousel 12 Plus Instructions Manual

Radleys Carousel 12 Plus Instructions Manual

Cooled reaction station

Advertisement

Quick Links

February 2023 | Issue 6
Instructions
Cooled Carousel 12 Plus
Reaction Station
These instructions should be read in conjunction
with the Carousel 12 Plus and Stirring Hotplate Instructions.
Your Local Distributor
Radleys
Shire Hill, Saffron Walden, Essex, CB11 3AZ. United Kingdom.
Tel: +44-1799-513320 Fax: +44-1799-513283
Email: sales@radleys.co
Web: www.radleys.com
m

Advertisement

Table of Contents
loading

Summary of Contents for Radleys Carousel 12 Plus

  • Page 1 Cooled Carousel 12 Plus ™ Reaction Station These instructions should be read in conjunction with the Carousel 12 Plus and Stirring Hotplate Instructions. Your Local Distributor Radleys Shire Hill, Saffron Walden, Essex, CB11 3AZ. United Kingdom. Tel: +44-1799-513320 Fax: +44-1799-513283 Email: sales@radleys.co...
  • Page 2 8.12. Setting and controlling the stirrer speed Page 12 8. Temperature Control Set-Up & Operation 8.13. Using the Cooled Carousel 12 Plus Lid 8.14. Using the Carousel 12 Plus Stand 8.15. Once your synthesis is complete 8.16. Disposing of used cooling fluid Page 13 9.
  • Page 3: Warranty

    These instructions should also be read in conjunction with the Carousel 12 Plus Instructions. 1. Introduction The Carousel 12 Plus is a modular system that provides the capability to perform parallel synthesis for reactions that require heating and/or cooling, in a fully inert atmosphere, and provides a streamlined interface to post synthesis processing.
  • Page 4: Safety Information

    4. Important WARNINGS Please read these instructions completely before using your Cooling Reservoir. These instructions should also be read in conjunction with the Carousel 12 Plus Instructions. • Operate only in a fume cupboard with protective safety sash. • The Cooled Carousel Reaction Station is NOT suitable for heated reactions •...
  • Page 5: Product Listing

    1 x RR98072 Carousel Stirring Hotplate 230v UK Plug 1 x RR98073 Carousel Temperature Controller 1 x RR91040 Carousel 12 Plus Cooling Reservoir & Lid 1 x RR99905 Digital Thermometer (-250˚C to +400˚C) & 200mm Probe 1 x RR99908 Dry Ice Scoop...
  • Page 6 Cooled Carousel 12 Plus Reaction Station 5. Product Listing - Continued Carousel 12 Plus Accessories & Spare Parts Caps & Tubes RR91070 Easy-On PTFE Cap RR91072 Easy-On PTFE Storage Cap RR98076 Silicone Septa for All Caps RR98176 Viton Silicone Septa for All Caps RR91080 Quick-Thread Glass Reaction Tube 24 ø...
  • Page 7 6.1. Carousel Cooling Reservoir The innovative Cooled Carousel 12 Plus reservoir is designed to accept the removable reflux/inerting head from the Carousel 12 Plus; allowing the reaction tubes to be easily and rapidly transferred between heating and cooling bases. The robust HDPE cooling reservoir features a unique non-drip spout and ergonomically...
  • Page 8 Cooled Carousel 12 Plus Reaction Station 7. Quick Start Guide 7.1. Assemble reflux head and cooling reservoir, so that they fit securely together. Make sure that the reflux head is properly seated on the central pillar of the reservoir. 7.2. Position cooled reservoir onto the stirring hotplate.
  • Page 9: Setup And Operation

    Cooled Carousel 12 Plus Reaction Station 8. Set-Up & Operation For reactions using the cooling reservoir 8.1. Assemble reflux head and cooling reservoir Place the reflux head on top of the central pillar of the cooling reservoir. The circular recess in the reflux head accepts the circular protrusion on the central pillar.
  • Page 10 Cooled Carousel 12 Plus Reaction Station 8. Set-Up & Operation - Continued 8.4. Assemble Reaction Tube and Easy-On Cap Select a suitable magnetic stirrer bar, and place in the reaction tube. We recommend the RR98091 Rare Earth - Medium Cross Shape PTFE Magnetic Stirring Bars for optimum stirring.
  • Page 11 Viton O-Rings 3mm Gas Outlet - Top, pk 50 8.8. Connect Reflux Coolant Supply For cooled reactions, reflux cooling is not required. Please refer to the Carousel 12 Plus Instructions for full details of the set-up and operation of reflux cooling.
  • Page 12 Cooled Carousel 12 Plus Reaction Station 8. Set-Up & Operation - Continued 8.10. Monitoring the coolant temperature For low temperature measurement we recommend use of the RR99905 Digital Thermometer (-250°C to +400°C) and 200mm Probe. The probe may be placed directly into the reservoir bowl to monitor the cooling mixture - by sliding the probe through the hole in the reflux head.
  • Page 13 8. Set-Up & Operation - Continued 8.13. Using the Cooled Carousel 12 Plus Lid The HDPE lid is included with your cooling reservoir. The lid is designed to keep your reaction cooler for longer, minimises condensation and ice formation on your tubes (maintaining vis- ibility of the contents) and prevents spitting from the cooling mixture.
  • Page 14 Preferably allow the cooling mixture to warm to room temperature before disposing of it according to appropriate local regulations The following protective equipment is available from Radleys: • RR71505 - Cooling Protection Kit, includes 1 x RR99909 Cold Temp. Apron 1060mm long Waterproof...
  • Page 15 Cooled Carousel 12 Plus Reaction Station Page 14...
  • Page 16 Page 2 of 2...
  • Page 18 Page 2 of 2...

Table of Contents