July 2018 Issue 7
Instructions
Carousel 6 Plus
Reaction Station
Your Local Distributor
Radleys, Shire Hill, Saffron Walden, Essex, CB11 3AZ. United Kingdom.
Tel: +44 1799 513320 Fax: +44 1799 513283
Email: sales@radleys.co.uk Web: www.radleys.com

Advertisement

loading

Summary of Contents for Radleys Carousel 6 Plus

  • Page 1 July 2018 Issue 7 Instructions Carousel 6 Plus ™ Reaction Station Your Local Distributor Radleys, Shire Hill, Saffron Walden, Essex, CB11 3AZ. United Kingdom. Tel: +44 1799 513320 Fax: +44 1799 513283 Email: sales@radleys.co.uk Web: www.radleys.com...
  • Page 2 Carousel 6 Plus Reaction Station Index Page 1 Index Page 2 1. Introduction Page 3 2. Warranty 3. Safety Information 4. Important WARNINGS Page 4 5. Product Component Guide Page 5 6. Products and Accessories Page 9 7. Glassware Page 11 8.
  • Page 3 Thank you for purchasing your Carousel 6 Plus Reaction Station. Please read this instruction manual thoroughly before operating your unit. The patented Carousel 6 Plus simultaneously heats, stirs and refluxes multiple samples under an inert atmosphere and accepts round bottom flasks of 5ml, 10ml, 25ml, 50ml, 100ml, 170ml and 250ml sizes.
  • Page 4 Please do not return any goods without prior agreement. 3. Safety Information The following symbols are intended to assist the user in the safe and efficient operation of the Carousel 6 Plus Reaction Station. Important Note Warning...
  • Page 5 Carousel 6 Plus Reaction Station 5. Product Component Guide Round aluminium base Easy-On Cap Easy-On Cap Easy-On Cap Wide Neck Reflux Tube Reflux Tube Rodaviss Connecting Set Wide Neck Coupling Wide Neck Flask Flask with Integrated Flask Reflux Tube Page 4...
  • Page 6 System 34 RR99943 Carousel 6 Plus System RR99916 - 1 x Carousel 6 Plus Reaction Station RR91070 - 1 x Easy-On PTFE Cap, pk 6 RR98076 - 1 x Silicone Septa for PTFE Caps, pk 100 RR98094 - 1 x PTFE Magnetic Stirring Bar Retriever 350mm...
  • Page 7 System 38 RR99949 Cooled Carousel 6 Plus System RR99947 - 1 x Cooled Carousel 6 Plus (Reservoir, Head, Stand + Cover) RR98024 - 1 x Protective Cold Temperature Gloves RR98076 - 1 x Silicone Septa for PTFE Caps, pk 100 RR99067 - 1 x Tubing for Inert Gas or Reflux Cooling 2 metres RR99905 - 1 x Digital Thermometer (-250˚C to +400˚C) + 200mm Probe...
  • Page 8 Carousel 6 Plus Systems RR99140 Aluminium Insert for 25ml Reaction Flask, pk 6 RR99942 Carousel 6 Plus System 33 - Heated System - Basic + Hotplate RR99060 Aluminium Insert for 50ml Reaction Flask, pk 6 RR99943 Carousel 6 Plus System 34 - Heated System - Basic...
  • Page 9 Pt1000 S/S Temperature Sensor with 345mm Probe Allows probe to reach through Tornado unit into Carousel 6 Plus base RR91227 Pt1000 Glass Coated Temperature Sensor Please contact Radleys for details of replacement parts for the Stirrer Guide and Tornado System. RR91228 Temperature Sensor Holder RR91235...
  • Page 10 1 x B24/29 Sidearm 7.3 Azeotropic Flasks (Dean and Stark) • Unique single piece flasks fit directly into the Carousel 6 Plus, allowing chemists to perform up to six azeotropic processes in parallel. • Choice of sizes: 100ml and 250ml.
  • Page 11 Flask with B24/29 Sidearm Flask with 2 x B24/29 Sidearms *The RR99935 and RR99937 250ml wide neck flasks with 2 x B24/29 sidearms (non-baffled and baffled) are not compatible with the RR99947 Cooled Carousel 6 Plus. 7.7 Sundry Glassware • Choice of 50ml liquid additions dropping funnels with B14/23 or B24/29 Rodaviss joints.
  • Page 12 Carousel 6 Plus Reaction Station 8. Quick Start Guide 8.1 Locate the Carousel on top of the stirring hotplate. 8.2 Place a magnetic stirring bar into your chosen reaction flask. 8.3 If you are using a flask that does not have an integrated reflux neck, attach an appropriate reflux tube.
  • Page 13 Carousel 6 Plus Reaction Station 9. Set-Up and Operation 9.1 Locating the Carousel 6 Plus on Stirring Hotplate The top surface of your stirring hotplate should be cleaned prior to use. Any small particles on the surface may affect the fit of the Carousel unit, and have an adverse affect on the performance.
  • Page 14 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued Selection of Glassware The Carousel is available with a range of unique glassware tailored for the specific requirements of parallel synthesis. You should select the glassware for your application based on volume, sidearm configuration, neck size and whether you need baffles or an azeotropic set-up.
  • Page 15 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued 9.5.3 Assembling Wide Neck Glassware 9.5.3 Wide Neck Component Guide • Position the lower coupling (2) around the neck of the flask (1) by prising it apart at the 6.
  • Page 16 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued Using Easy-On Caps 9.7B 9.7A When using the Easy-On caps, to ensure the flow of inert gas, the valve must be in the ‘open’ position (see 9.7A). A quarter turn (anti-clockwise or clockwise) will ‘close’ the valve, isolating the reaction flask (see 9.7B).
  • Page 17 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued 9.10 Connect Gas/Vacuum Supply The central gas inlet/outlet and radial distribution system combined with Easy-On PTFE caps allow reactions to be performed under an inert (nitrogen/argon) atmosphere. For use under an inert atmosphere attach tubing to the central quick-release coupling and connect via a 3-way tap or stopcock to a vacuum source and inert gas supply (recommended maximum pressure 1psi).
  • Page 18 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued 9.13 Temperature Control 9.13.1 9.13.1 Set the stirring speed and temperature of the stirring hotplate to the desired level. 9.13.2 The stainless steel temperature sensor is positioned either in one of the reaction flasks (through the silicone septa) to monitor and control the solution temperature (9.13.2A) or into the reaction block via the hole between the reflux inlets (9.13.2B).
  • Page 19 Carousel 6 Plus Reaction Station 9. Set-Up and Operation - Continued 9.15 Important Tips for Optimum Refluxing 9.15.1 For most solvents a water supply of 5˚C to 18˚C will be sufficient for effective reflux- ing. However with cooling water above 12˚C, care should be taken to carefully control refluxing.
  • Page 20 Carousel 6 Plus Reaction Station 10. Performance Data - Insulating Plate 10.1 Use of the PTFE Insulating Plate as a Safety Barrier The insulating properties of the PTFE material provide a significant safety barrier, protecting the user from high temperatures and reducing the risk of serious burn, in case of accidental contact when the reactor is being used at elevated temperatures.
  • Page 21 Carousel 6 Plus Reaction Station 11. Radleys/Genevac Rack Compatibility Guide Page 20...
  • Page 22 Warranty – Email Back Carousel 6 Plus Reaction Station sales@radleys.co.uk To qualify for your warranty please complete, scan and email this form to Radleys Date of Purchase ........................................................ Supplier’s Name and Address .................................................... Product Batch/Serial No. (if shown) ................................................Your Details...