Eastron SDM630-2T User Manual

Eastron SDM630-2T User Manual

Din rail smart meter for single and three phase electrical systems

Advertisement

Quick Links

EASTRON SDM630-2T V2 User Manual
SDM630-2T V2
DIN Rail Smart Meter for Single and Three Phase Electrical Systems,
Measures kWh Kvarh, KW, Kvar, KVA, P,
F, PF, Hz, dmd, V, A, etc.
Bi-directional measurement IMP & EXP
Two pulse outputs
RS485 Modbus/M-bus
Din rail mounting 35mm
100A direct connection
Better than Class 1 / B accuracy
Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
Tel: 0086-573-83698881/83698882 Fax: 0086-573-83698883 Web: www.eastron.com.cn
USER MANUAL
2016 V1.1

Advertisement

loading

Summary of Contents for Eastron SDM630-2T

  • Page 1 EASTRON SDM630-2T V2 User Manual SDM630-2T V2 DIN Rail Smart Meter for Single and Three Phase Electrical Systems, Measures kWh Kvarh, KW, Kvar, KVA, P,  F, PF, Hz, dmd, V, A, etc. Bi-directional measurement IMP & EXP  Two pulse outputs ...
  • Page 2 60 minutes. In order to measure energy, the unit requires voltage and current inputs in addition to the supply required to power the product. SDM630-2T supports max. 100A direct connection, saves the cost and avoid the trouble to connect external CTs, giving the unit a cost-effective and easy operation. Built-in interfaces provide pulse and RS485 Modbus RTU or M-bus outputs.
  • Page 3 EASTRON SDM630-2T V2 User Manual 100ms.The configurable pulse output 1 can be set from the set-up menu. Start-up Screens The first screen lights up all display segments and can be used as a display check second screen indicates firmware installed in the unit and its build number.
  • Page 4 EASTRON SDM630-2T V2 User Manual Voltage and Current Each successive pressing of the button selects a new range: Phase to neutral voltages(3p4w) Phase to neutral voltages(3p3w) Current on each phase Phase to neutral voltage THD%(3p4w) Phase to neutral voltage THD%(3p3w) Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 5 EASTRON SDM630-2T V2 User Manual Current THD% for each phase Frequency and Power factor and Demand Each successive pressing of the button selects a new range: Frequency and Power Factor (total) Power Factor of each phase Maximum Power Demand Maximum Current Demand...
  • Page 6 EASTRON SDM630-2T V2 User Manual Instantaneous Active Power in kW Instantaneous Reactive Power in kVAr Instantaneous Volt-amps in KVA Total kW, kVArh, kVA Energy Measurements Each successive pressing of the button selects a new range: Imported active energy in kWh Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 7 EASTRON SDM630-2T V2 User Manual Exported active energy in kWh Imported reactive energy in kVArh Exported reactive energy in kVArh Total active energy in kWh Total reactive energy in kVArh Tariff 1 active energy in kWh Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China.
  • Page 8 EASTRON SDM630-2T V2 User Manual Tariff 2 active energy in kWh Set-up To enter set-up mode, pressing the button for 3 seconds, until the password screen appears. Setting up is password-protected so you must enter the correct password (default ‘1000’) before processing.
  • Page 9 EASTRON SDM630-2T V2 User Manual 4) Having selected an option from the current layer, press to confirm your selection. The SET indicator will appear. 5) Having completed a parameter setting, press to return to a higher menu level. The SET indicator will be removed and you will be able to use the buttons for further menu selection.
  • Page 10 EASTRON SDM630-2T V2 User Manual to set the first digit and press to confirm your selection. The next digit will flash. Repeat the procedure for the remaining three digits After setting the last digit, SET will show. Press to exit the number setting routine and return to the Set-up menu. SET will be...
  • Page 11 EASTRON SDM630-2T V2 User Manual buttons to select the time required. Press to confirm the selection. SET indicator will appear. Press to exit the DIT selection routine and return to the menu. Backlit set-up The backlit lasting time is settable Default lasting time is 60minutes For example, if it’s set as 5, the backlit...
  • Page 12 EASTRON SDM630-2T V2 User Manual Use this section to set the type of power supply being monitored. From the Set-up menu, use buttons to select the System option. The screen will show the currently selected power supply. Press to enter the selection routine.
  • Page 13 EASTRON SDM630-2T V2 User Manual From the Set-up menu, use buttons to select the Pulse output option. Press to enter the selection routine. The unit symbol will flash. buttons to choose kWh or kVArh. On completion of the entry procedure, press to confirm the setting and press to return to the main set up menu.
  • Page 14 EASTRON SDM630-2T V2 User Manual Press to enter the selection routine. The current setting will flash. Note: When it’s dFt, it means 2.5Wh/VArh buttons to choose pulse rate. On completion of the entry procedure, press to confirm the setting and press to return to the main set up menu.
  • Page 15 EASTRON SDM630-2T V2 User Manual Communication There is a RS485 port can be used for communication using Modbus RTU protocol. For Modbus RTU, parameters are selected from Front panel. For M-bus version, there is a Mbus port can be used for communication using Mbus protocol. For Mbus communication, parameters are selected from Front panel.
  • Page 16 EASTRON SDM630-2T V2 User Manual On completion of the entry procedure, press button to confirm the setting and press button to return the main set-up menu. Baud Rate From the Set-up menu, use buttons to select the Baud Rate option.
  • Page 17 EASTRON SDM630-2T V2 User Manual Press to enter the selection routine. The current setting will flash. buttons to choose Parity (EVEN / ODD / NONE) On Completion of the entry procedure, press to confirm the setting and press to return to the main set up menu.
  • Page 18 EASTRON SDM630-2T V2 User Manual to return to the main set up menu. Note: Default is 1, and only when the parity is NONE that the stop bit can be changed to 2. The meter provides a function to reset the maximum demand value of current and power.
  • Page 19 EASTRON SDM630-2T V2 User Manual Energy Measurements Imported active energy 0 to 999999.99 kWh  Exported active energy 0 to 999999.99 kWh  Imported reactive energy 0 to 999999.99 kVArh  Exported reactive energy 0 to 999999.99 kVArh  Total active energy 0 to 999999.99 kWh...
  • Page 20 EASTRON SDM630-2T V2 User Manual Pulse Output The unit provides two pulse outputs. Both pulse outputs are passive type. Pulse output 1 is configurable. The pulse output can be set to generate pulses to represent total / import/export kWh or kVarh.
  • Page 21 EASTRON SDM630-2T V2 User Manual Environment Operating temperature -25°C to +55°C*  Storage temperature -40°C to +70°C*  Relative humidity 0 to 90%, non-condensing  Altitude Up to 2000m  Warm up time 1 minute  Vibration 10Hz to 50Hz, IEC 60068-2-6, 2g ...
  • Page 22 EASTRON SDM630-2T V2 User Manual Wiring diagram Three Phase Three Wires:  (M-bus Version) Three Phase Four Wires:  (M-bus Version) Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. - 21 Tel: 0086-573-83698881/83698882 Fax: 0086-573-83698883 Web: www.eastron.com.cn...
  • Page 23 EASTRON SDM630-2T V2 User Manual Single Phase two Wires:  (M-bus Version) Address: No.1369 Chengnan Road, Jiaxing, Zhejiang, 314001, China. - 22 Tel: 0086-573-83698881/83698882 Fax: 0086-573-83698883 Web: www.eastron.com.cn...