Eastron SDM630MCT-ML-TCP User Manual

Eastron SDM630MCT-ML-TCP User Manual

Quad loads multifunctional energy meter

Advertisement

Quick Links

SDM630MCT-ML-TCP User Manual 2021 V1.0
Quad Loads Multifunctional Energy Meter
SDM630MCT-ML-TCP
User manual V1.0
2021 EASTRON ELECTRONIC.
ALL RIGHTS RESERVED.
www.eastrongroup.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SDM630MCT-ML-TCP and is the answer not in the manual?

Questions and answers

Summary of Contents for Eastron SDM630MCT-ML-TCP

  • Page 1 SDM630MCT-ML-TCP User Manual 2021 V1.0 Quad Loads Multifunctional Energy Meter SDM630MCT-ML-TCP User manual V1.0 2021 EASTRON ELECTRONIC. ALL RIGHTS RESERVED. www.eastrongroup.com...
  • Page 2 SDM630MCT-ML-TCP User Manual 2021 V1.0 Zhejiang Eastron Electronic Co.,Ltd. Statements All rights reserved. Without the written permission of the company, no paragraphs or chapters in this manual can be extracted, copied or reproduced in any form. Otherwise, the violator shall bear all consequences.
  • Page 3: Table Of Contents

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Content Chapter 1. Introduction........................- 1 - 1.1 Introduction..........................- 1 - Product Characteristics......................- 1 - Application..........................- 2 - Chapter 2. Technical Parameters ......................- 2 - 2.1Technical parameters........................- 2 - 2.2 Accuracy............................. - 2 - Ethernet communication......................
  • Page 4 SDM630MCT-ML-TCP User Manual 2021 V1.0 3.4.7 System Type Setup......................- 14 - 3.4.8 Password Modification Setup................... - 14 - 3.4.9 Ethernet information Setup .................... - 14 - 3.4.10 CT Reverse Connect Correction..................- 15 - 3.4.11 Reset..........................- 18 - Chapter 4. Communication....................... - 19 - 4.1 Connection Diagram for Communication................
  • Page 5: Chapter 1. Introduction

    80% installation time and avoiding wiring mistakes. The SDM630MCT-ML-TCP is compactly designed. It can be used as 4x three phase energy meters or 12x single phase energy meters. 100mA (100mV optional) secondary external CT is required to work with the meter.
  • Page 6: Application

    SDM630MCT-ML-TCP User Manual 2021 V1.0 1.3 Application SDM630MCT-ML-TCP is suitable for scenarios where multi-loads are required. Chapter 2. Technical Parameters 2.1 Technical parameters  Voltage AC (Un): 3*230/400VAC Voltage range: 50 - 600VAC Auxiliary power supply: 85 - 300VAC  Current input: Primary current input: 1 - 9999A Secondary current input: 100mA (optional:100mV)
  • Page 7: Performance Criteria

     Gateway: 192.168.1.1  DHCP: Off (default) Note: SDM630MCT-ML-TCP has 2 modes of Modbus communication address. The modes can be set by pressing the buttons on the meter or via Ethernet Modbus TCP. Mode 1: Single communication address mode. Under this mode, the register address of different channels (CH01-CH04) will be showed in segments.
  • Page 8: Wiring Diagram

    SDM630MCT-ML-TCP User Manual 2021 V1.0 2.6 Wiring diagram 2.6.1 Three Phase 4 Wires 2.6.2 Three Phase 3 Wires 2021 EASTRON ELECTRONIC. ALL RIGHTS RESERVED. www.eastrongroup.com...
  • Page 9: Single Phase 2 Wires

    SDM630MCT-ML-TCP User Manual 2021 V1.0 2.6.3 Single Phase 2 Wires 2.6.4 Single Phase 3 Wires 2021 EASTRON ELECTRONIC. ALL RIGHTS RESERVED. www.eastrongroup.com...
  • Page 10: Chapter 3. Operation

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Chapter 3. Operation 3.1 Installation display The first screen lights up all display segments and can be used as a display check. The second screen indicates the firmware installed in the unit. Note:the actual display might be different with the left on here.
  • Page 11: Measurements

    SDM630MCT-ML-TCP User Manual 2021 V1.0 3.3 Measurements 3.3.1 Voltage and current Each successive pressing of the button selects a new range: Phase to neutral voltage Phase to neutral voltage(1p3w only) Phase to phase voltage Phase to phase voltage (1p3w only)
  • Page 12: Frequency, Power Factor And Demand

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Curret on netural Phase to neutral voltage THD% Phase to neutral voltage THD% (3p3w only) Phase to neutral current THD% Phase to neutral current THD%(1p3w only) 3.3.2 Frequency, Power factor and Demand Each successive pressing of the...
  • Page 13: Power

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Power Factor of each phase Maximum current demand on each phase Maximum total power demand 3.3.3 Power Each successive pressing of the button select a new range: Instantaneous Active Power in kW Instantaneous Reactive Power in kVAr Instantaneous Volt-amps in kVA 2021 EASTRON ELECTRONIC.
  • Page 14: Energy

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Total kW, kVArh, kVA 3.3.4 Energy Each successive pressing of the button shows following measurements: Total active energy in kWh Total reactive energy in kVArh imported active energy in kWh Exported active energy in kWh Imported reactive energy in kVArh 2021 EASTRON ELECTRONIC.
  • Page 15: Setup Mode

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Exported reactive energy in kVArh 3.4 Setup Mode The meter’s settable parameters are password protected. By long pressing the 4th button “E”, the user can get into the setup mode. 3.4.1 Password Validation Press button to enter password.
  • Page 16 SDM630MCT-ML-TCP User Manual 2021 V1.0 Press to setup communication address. Long press to confirm. Option:1, M* (default) 1 means one communication address mode; M* means multi communication addresses. It can be 2 or 3 or 4. It depends on the meter you have is for dual loads, or tri-loads or quad-loads.
  • Page 17: Ct2 Check

    SDM630MCT-ML-TCP User Manual 2021 V1.0 3.4.3 CT2 check Check only, not settable. Note: if the unit is 100mA input version, the CT2 check will show 0.1A. 3.4.4 CT1 setup Long press button to enter the setup. Press button to choose the right channel (CH01-CH04).
  • Page 18: Backlit Power Time Setup

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Press button to set the demand period value. Long press button to confirm. Option: 5, 8, 10, 15, 20, 30, 60(default),off, Unit: min. 3.4.6 Backlit Power Time Setup Long press button to enter the setup.
  • Page 19: Ethernet Information Setup

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Press button to enter the new password. Long press button to confirm. Range:0000~9999, default 1000. 3.4.9 Ethernet information setup 3.4.9.1 DHCP function setup Long press button to enter the setup mode of TCP IP information.
  • Page 20 SDM630MCT-ML-TCP User Manual 2021 V1.0 Long press button to enter the setup mode. Subnet mask-High 255.255 (default) Subnet mask-Low 255.0 (default) 3.4.9.4 TCP gateway address setup Long press button to enter the setup mode of IP address of TCP gateway TCP gateway address - High: 192.168 (default)
  • Page 21: Ct Reverse Connect Correction

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Long press button to enter the setup mode of TCP IP port TCP IP port: 502(default) 3.4.10 CT Reverse Connect Correction If the CT is reversely connected, the user does not need to disconnect and reconnect the cables. By this setting adjustment, the meter will automatically adjust the current direction.
  • Page 22: Reset

    SDM630MCT-ML-TCP User Manual 2021 V1.0 3.4.11 Reset This function allows user to reset data. Long press button to choose channel. Channel Selection interface Press button to choose channel (CH01-CH04). Long press to enter the reset confirmation interface. Press button to choose the data type.
  • Page 23: Connection Diagram For Communication

    SDM630MCT-ML-TCP User Manual 2021 V1.0 Chapter 4. Connection Diagram for Communication If you have any question, please feel free to contact our sales team. Zhejiang Eastron Electronic Co., Ltd. No.1369, Chengnan Rd. Jiaxing, Zhejiang, 314001, China Tel: +86-573-83698881 Fax: +86-573-83698883 Email: sales@eastrongroup.com...

Table of Contents