Troubleshooting - Hoover RMB9800/1IN Instruction Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

TROUBLESHOOTING

Fault
Light on, but motor
does not work
Light does not
work, motor does
not work
Oil leakage
Lights not working
Insufficient suction
The Cooker hood
inclines
NOTE:
Any electrical repairs to this appliance must conform to your local, state and
federal laws.Please contact the service centre if in any doubt before
undertaking any of the above.Always disconnect the unit from the power source when
opening the unit.
Possible Cause
Fan switch turned off
Fan switch failed
Motor failed
House fuses blown
Power cord loose or
disconnected
One way valve and the air
ventilation entrance are not
tightly sealed
Leakage from the connection of
U-shaped section and cover
Broken/Faulty globes
The distance between the
cooker hood and the gas top is
too far
The fixing screw not tight
enough
Select a fan switch position.
Contact service center.
Contact service center.
Reset/Replace fuses.
Refit cord to power outlet. Switch
power outlet on.
Take down the one way valve
and seal with sealant.
Take U-shaped section down
and seal.
Replace globes as per this
instruction.
Refit the cooker hood to the
correct distance.
Tighten the hanging screw and
make it horizontal.
9
Solution

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rmb9600/1inHmb9600/1xHmb6600/1x

Table of Contents