Comfort Bilt HP50S Owner's Manual page 26

Hide thumbs Also See for HP50S:
Table of Contents

Advertisement

Operation
Settings Continued
4: Set Ash Cleaning Cycle
set for a specific heating level. (H01 - H05)
Press the Up and Down arrows to navigate to the line item you
wish to edit, and press Enter to highlight.
Press Up and Down to edit the value, then press Enter again to
confirm.
1.
Time Span: Controls the time span between cleaning cycles. (Minutes)
2.
Duration: Controls how long the cleaning cycle will last. (Seconds)
3.
Smart Ash Cleaning: Allows the stove to use a pre-set range of numbers. Gives the option for Light,
Medium, and Heavy cleaning cycles. (Activating this option will gray out the Time Span and Duration
options)
When the stove enters into a "Cleaning" phase, the feeder will pause, and the exhaust fan will increase to let
some of the buildup of ash in the burn pot get blown free. (If you experience a very small flame or "Low
Temperature" alerts during this cleaning cycle, reducing the Duration value to 20 Sec or less on level: H01
may help)
5: Set ECO
- This menu lets you toggle on or off the ECO function,
which will allow the stove to automatically cycle on and off based on
the desired temperature set in the Temp mode.
Press the Enter button to highlight the Off or On tag.
Press the Up or Down button to edit the value, and then press
Enter to confirm.
When ECO is set to ON, and the stove is operating in the "Temp" mode, the stove will go into "Fire off" mode
and shut down when the actual temperature (in the house) meets or exceeds the desired, or call to,
temperature (left side of screen)
Once the exhaust housing is cool, and the actual temperature falls below the desired temperature, then the
stove will automatically reignite.
This On/Off cycle will continue until interrupted or turned off.
*ECO will cause considerable wear on the igniter, and require more electricity during the added ignition
phases.
6: Diagnosis
- This menu allows you to independently test each of
the main components of the stove. You can only enter into the
Diagnosis menu when the stove is off and the work stage line
shows "Stop" (at the top left, below the Operational mode)
Press the Enter button to cycle through the four main
components. Fire, Exhaust, Feed, and Blow.
Pressing the Up button will place a shaded circle next to the
selected component and activate that device.
Level: This lets you simulate what level the activated device will run at. (H01 - H05)
Fire: Putting a shaded circle here will engage the Igniter. (Once activated the igniter should glow at the tip
within 3 minutes)
Exhaust: Putting a shaded circle here will engage the combustion fan.
Feed: Putting a shaded circle here will engage the auger system and feed pellets. (at the level indicated)
Blow: Putting a shaded circle here will engage the room blower fan.
Limit: This will engage and become shaded when the hopper lid is closed.
Vacuum: This will engage and become shaded when the main chamber is under negative pressure. (anytime
the combustion fan is running)
POF: (Proof of Fire) This will engage when the exhaust housing is hot. (above 130° F)
Hopper T: This will display the current temperature of the Hopper temp sensor. (Alerts above 197°F)
Room T: This will display the current temperature of the room. (Room temperature sensor behind stove)
- This menu has three options that are