Installation
Simple Horizontal Installation
Appliance Adapter
Floor Protection
Notice: Excessive embers/sparks can exit exhaust cap if
less than 4 ft of venting is used with no vertical rise.
Simple Vertical Installation (preferred)
Appliance Adapter
Floor Protection
Wall Thimble
Wall
Air Intake
90° Elbow
Exhaust cap
Wall strap
Wall Thimble
Wall
Clean-out Tee
Air Intake
Notice: For Canada, the installation must conform to CAN/CSA-B365
Mobile Home Installation
Installation in a mobile home should be in
accordance with the manufactured home and
safety standard (HUD),
stove must be vented to the outside. In addition to
the standard installation instructions, the following
requirements are mandatory for installation in a
mobile home:
The stove must be permanently attached to the
floor.
Exhaust cap
Stove must have an outside air source.
Stove must be electrically grounded to the steel
chassis of the mobile home, unless grounded
power outlets are provided.
All vertical chimney vents must have wall
supports.
All exhaust systems must have a spark
arrestor.
Check with local building officials to see if other
codes may apply.
Structural integrity of the floor, wall and
ceiling/roof must be maintained.
Floor Protection
14
CFR 3280, Part
24. This
Wall Thimble
90° Elbow
Exhaust cap
Wall
Clean-out Tee
Air Intake
Appliance Adapter
comfortbilt.net