Operation
pressurizing becomes.

Method of operation

Condition of use
Rapid
Cooling
Normal
Dehumidifying,
heating
Rapid
Heating
Normal
Defroster
Vetilation or
pressurizing
When carrying out the defrosting, if the temperature control
switch is set so that all lamps are red, this will improve the per-
formance for defrosting and demisting.
Set the vent mode selector switch to the intermediate position to
give the desired condition.
With the FACE vents, it is possible to adjust the direction of the
air flow and to turn it on or off.
However, do not set to the FACE mode with the vents closed.
When not using the air conditioner regularly
Run the air conditioner at cooling or dehumidification + heating
for several minutes from time to time to prevent the loss of the oil
film at various parts of the compressor.
REMARK
If the temperature inside the cab is low, the air conditioner
may not work. In such cases, use the recirculated air to
heat up the inside of the cab, then turn the air conditioner
switch on to run the air conditioner.
WA150-5H – VEAM934100
Air conditioner
Fan switch
switch
HI
ON
HI-LO
ON
HI-LO
ON
HI
OFF
HI-LO
OFF
HI
ON
HI-LO
OFF
3.2 Explanation of components
Switchs
Temperature
FRESH/RECIRC
control switch
selector switch
All blue
RECIRC
More than half
FRESH
are blue
More than half
FRESH
are red
All red
RECIRC
More than half
FRESH
are red
More than half
FRESH
are red
All blue
FRESH
Mode selector
switch
FACE
FACE
FOOT
FOOT
FOOT
DEF
FACE
GK032171
GK032169
3-53