Download Print this page

Mercia Garden Products 01PTGRO0705-V2 General Instructions Manual

Advertisement

Quick Links

General Instructions
01PTGRO0705-V2
Pressure treated Groundsman 7x5
BEFORE YOU START PLEASE READ INSTRUCTIONS CAREFULLY
- Check the pack and make sure you have all the parts listed.
- When you are ready to start, make sure you have the right tools at hand (not supplied) including a Phillips screw-
driver, Stanley knife, wood saw, step ladder and drill with 2mm bit.
- Ensure there is plenty of space and a clean dry area for assembly.
TIMBER
As with all natural materials, timber can be a ected during various weather conditions. For the duration of heavy
or extended periods of rain, swelling of the wood panels may occur. Warping of the wood may also occur during
excessive dry spells due to an interior moisture loss. Unfortunately, these processes cannot be avoided but can be
helped. It is suggested that the outdoor building is sprayed with water during extended periods of warm sunshine
and sheltered as much as possible during rain or snow.
Once your garden building has been installed it will need to be treated as soon as possible and annually to prevent
the timber from deteriorating and to waterproof it. This is required to maintain the anti-rot guarantee.
Dip Treated buildings - Require a preservative treatment to protect against rot and decay and a waterproof treat-
ment to prevent water ingress
Pressure Treated buildings - Require a waterproof treatment to prevent water ingress
Log Cabins - Are supplied untreated and require a preservative and waterproo ng treatment.
BUILDING A BASE
When thinking about where the building and base is going to be constructed:
Ensure that there will be access to all sides for maintenance work and annual
treatment.
Ensure the base is level and is built on rm ground, to prevent distortion. Refer to diagrams for the base
dimensions, The base should be slightly smaller than the external measurement of the building, i.e. The cladding
should overlap the base, creating a run o for water. It is also recommended that the oor be at least 25mm above
the surrounding ground level to avoid ooding.
TYPES OF BASE
- Concrete 75mm laid on top of 75mm hard-core.
- Slabs laid on 50mm of sharp sand.
Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens
products independently tested to EN71 level, we cannot accept responsibility for your safety whilst erecting or
using this product.
Refer to the instructions pages for you speci c product code
Please retain product label and instructions for future reference
x2
All building's should be
erected by two adults
For ease of assembly, you
MUST pilot drill all screw
holes and ensure all screw
heads are countersunk.
2mm Drill bit
For ease of assembly, you
will need a tape measure to
check dimensions of
components.
Pressure Treated Timber
Pressure treating is a chemical process which helps to protect wood against adverse weather which could
lead to rot or insect damage.
The most common chemicals used to pressure treat wood are Alkaline Copper Quaternary (ACQ),
Copper Azole (CA), and Micronized Copper Quaternary (MCQ).
Safety: Always wear gloves, eye protection and a dust mask when handling wood. Due to chemicals in
pressure treated wood, never burn its sawdust or scraps; instead dispose in a land ll.
For assistance please contact customer care on: 01636 880514
Mercia Garden Products Limited,
Sutton On Trent,
Newark,
Nottinghamshire,
NG23 6QN
www.merciagardenproducts.co.uk
Winter = High Moisture = Expansion
Summer = Low Moisture = Contraction
CAUTION
Every e ort has been made during the
manufacturing process to eliminate the
prospect of splinters on rough surfaces of the
timber. You are strongly advised to wear gloves
when working with or handling rough sawn
timber.
P 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the 01PTGRO0705-V2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Mercia Garden Products 01PTGRO0705-V2

  • Page 1 - Concrete 75mm laid on top of 75mm hard-core. - Slabs laid on 50mm of sharp sand. Mercia Garden Products Limited, Whilst all products manufactured are made to the highest standards of Safety and in the case of childrens Sutton On Trent,...
  • Page 2 01PTGRO0705-V2 Please retain product label and instructions for future reference Overall Dimensions: Fixing Kit Length = 2208mm Width = 1650mm Height = 2043mm Base Dimensions: Fascia - 12x95x930mm Qty 4 - Length = 2082mm S1295-930MM Width = 1479mm Window Strip - 12x45x1100mm -...
  • Page 3 Please retain product label and instructions for future reference Step 3 Step 1 Place the oor on a rm and Fix the T-hinges onto the level base, ensure base has door and door gable as suitable drainage free from shown. using 30mm areas where standing water screws.
  • Page 4 Please retain product label and instructions for future reference Step 5 Step 7 Fix the corners with 3x Cut the felt into two sheets For buildings with no windows 50mm screws as shown in x a plain panel here. measuring 2284mm. Lay diagram.
  • Page 5 Please retain product label and instructions for future reference Step 8 Step 10 Fit the cover trims to the front and back of the building as shown in the illustration 30mm using 30mm screws. screw Place the opening window strip Trim the length of the cover 11mm above the window gap in the trims to the required size...
  • Page 6: After Treatment

    Please retain product label and instructions for future reference Step 11 Step 12 Fix the casement stay to the opening window then align To x the lock in place. Screw the Staple the xings onto the window to the Door Gable or Slave door. panel frame.