Trane A4AH5E19A1B30A Installer's Manual page 27

Convertible air handlers 1–1/2 — 5 ton
Table of Contents

Advertisement

11. Secure each bracket with a screw that were
previously removed.
Figure 11. All models
12. Slide the coil assembly back into the air handler
cabinet as shown.
13. Remove the appropriate knock out for the
condensate piping.
Figure 12. All models
18-GF15D1-1B-EN
C C o o i i l l C C o o n n v v e e r r s s i i o o n n I I n n s s t t r r u u c c t t i i o o n n s s
14. Replace all panels.
Figure 13. All models
H H o o r r i i z z o o n n t t a a l l R R i i g g h h t t
Follow the conversion steps when installing the air
handler in horizontal right configuration.
1. Remove the front panels from the air handler. The
coil and line set panel do not need to be separated.
2. Remove the fasteners on both sides of the coil.
Retain the coil retaining brackets and screws.
3. Remove the two screws holding the center
horizontal bracket and rotate out of place. Retain
parts.
27