Trane A4AH5E19A1B30A Installer's Manual page 6

Convertible air handlers 1–1/2 — 5 ton
Table of Contents

Advertisement

I I n n s s t t a a l l l l a a t t i i o o n n I I n n s s t t r r u u c c t t i i o o n n s s
Vent
-This vent pipe MUST
terminate above the
dotted line
To Drain
Cleanout
(Plug)
Insulate the primary drain line to prevent sweating
where dew point temperatures may be met.
(Insulation is optional depending on climate and
application needs.)
5. R R e e f f r r i i g g e e r r a a n n t t P P i i p p i i n n g g
Refrigerant piping external to the unit shall be sized
in accordance with the instructions of the
manufacturer of the outdoor equipment.
6. M M e e t t e e r r i i n n g g D D e e v v i i c c e e
All units are shipped and installed with an
internally-checked, non-bleed TXV designed for air
conditioning or heat pump operation. Some
outdoor models may require a start assist kit. See
outdoor unit for more information.
7. M M u u l l t t i i - - S S p p e e e e d d B B l l o o w w e e r r s s ( ( A A 4 4 A A H H 5 5 E E * * ) )
This unit is supplied with a multi-speed motor with
a direct drive blower wheel which can obtain
various air flows. The unit is shipped with factory
set cooling and heating speed taps. Airflow
performance tables are available for additional
speed taps. Disconnect all power to the unit before
making any adjustments to the motor speed taps.
Be sure to check the air flow and the temperature
drop across the evaporator coil to ensure sufficient
air flow.
8. V V a a r r i i a a b b l l e e - - S S p p e e e e d d B B l l o o w w e e r r s s ( ( A A 4 4 A A H H 5 5 V V * * ) )
This unit is supplied with a variable speed motor
with a direct drive blower wheel which can obtain
various air flows. The unit is shipped with factory
set cooling and heating air flows. Performance
tables are available for additional airflow settings.
Disconnect all power to the unit before making any
adjustments to the airflow settings. Be sure to
check the air flow and the temperature drop across
the evaporator coil to ensure sufficient air flow.
9. A A i i r r f f l l o o w w A A d d j j u u s s t t m m e e n n t t
6
Cleanout
(with Cap)
C C A A U U T T I I O O N N
E E Q Q U U I I P P M M E E N N T T D D A A M M A A G G E E ! !
F F a a i i l l u u r r e e t t o o f f o o l l l l o o w w t t h h i i s s p p r r o o c c e e d d u u r r e e m m a a y y r r e e s s u u l l t t i i n n
e e q q u u i i p p m m e e n n t t d d a a m m a a g g e e . .
D D i i s s c c o o n n n n e e c c t t p p o o w w e e r r t t o o t t h h e e a a i i r r h h a a n n d d l l e e r r b b e e f f o o r r e e
c c h h a a n n g g i i n n g g d d i i p p s s w w i i t t c c h h p p o o s s i i t t i i o o n n s s . .
Blower speed changes are made on the ECM Fan
Control. The ECM Fan Control controls the variable
speed motor.
There is a bank of 8 dip switches. The dip switches
work in pairs to match the airflow for the outdoor
unit size (tons). cooling airflow adjustment, Fan off-
delay options, and heating airflow adjustment.
Figure 1. ECM Fan Control
Figure 2. Dip Switches
COOLING
HEATING
AIRFLOW
DIP SWITCHES (TYPICAL SETTINGS)
If the airflow needs to be increased or decreased,
see the Airflow Label on the air handler or Blower
Performance Table.
Be sure to set the correct airflow for cooling and
heating.
Switches 1–4 Cooling Airflow
Switches 5–6 Fan Off Delay Options
Switches 7–8 Auxiliary Heat
I I n n d d o o o o r r B B l l o o w w e e r r T T i i m m i i n n g g
I I m m p p o o r r t t a a n n t t : : Leave dip switches 5 and 6 in the "as-
shipped" positions during system start-
up and check out. Afterwards, adjust as
desired.
FAN OFF
AUXILARY
DELAY
HEAT SPEEDS
18-GF15D1-1B-EN