JA-16A RB Wireless outdoor battery-powered siren
The JA-16A RB is a component of the JA-10 system. It is used for
system alarm indication outside a building. It can also be used
for supplementary acoustic signalling (PG activation, arming, chirps).
The siren is powered by just one lithium battery with no other external
power. The JA-16A RB consists of the JA-16A-BASE-RB base with
the PCB, the BAT-100A lithium battery and the JA-1XA-C-WH cover.
The siren occupies one position in the system.
Installation
The whole enrolment procedure has to be done in service mode
of the control panel. There must be a JA-111R radio module
installed in the control panel.
Figure 1: 1 – hole for installing; 2 – piezo sounders; 3 – BAT-100A lithium battery
with reusable battery strap (up to 2 batteries can be used); 4 – PCB;
5 – spirit level; 6 – hole for installation with tamper detection; 7 – front cover
screw; 8 – string with clip connecting the front cover for easy installation
The siren should be installed on a vertical wall,
with the flasher facing downwards. Avoid
installing the siren near the gutters and on other
places
where
accumulation.
1. Attach the siren onto a suitable place using 2 screws through the
holes (1) and (6). The spirit level can be used for easy
installation (5).
2. Connect the BAT-100A lithium battery (3) to the connector (11).
3. Proceed according to the control panel installation manual.
Basic procedure:
a. When the battery is connected, the yellow LED (12) indicates
by a permanent light that the siren has not been enrolled into
the system yet.
b. Go to the N-Link software, select the required position
in the Devices tab and launch the enrolment mode by clicking
on the Enroll option.
c. Press the button marked LEARN (10) – the siren is thus
enrolled and the yellow LED indicator goes off.
4. Put back the siren cover and attach it using the screw (7).
5. Perform siren properties setting, for more detail see the chapter:
Internal settings of the siren.
Notes:
The siren can also be enrolled into the system by entering
its production code (9) in the N-Link software. You can find
the production code on the sticker, glued on the PCB.
All numbers under the bar code shall be entered (1400-00-
0000-0001).
The siren can be powered by up to two BAT-100A batteries and
we recommend this when longer siren operation time is required.
There is a place prepared for second battery use see Figure 1.
Connect the battery to the other connector (11). The battery
connection order doesn´t matter.
JA-16A RB Wireless outdoor battery-powered siren
there
is
a
danger
of
ice
Figure 2: 9 – production code; 10 – LEARN (enrollment) button;
11 – battery connector; 12 – yellow fault indicator; 13 – mini USB connector;
14 - piezo siren connection (attention: high voltage); 15 – external antenna
connector; 16 - high intensity red LED flashers
Erasing the siren from system / RESET
Use this procedure when the siren has to be erased from one
system and enrolled to another one. Proceed this way:
1. The control panel has to be in Service mode.
2. Open the siren cover and disconnect the BAT-100A battery
from its connector.
3. Go to the N-Link software, Devices tab, and erase the siren
from the control panel and leave service mode.
4. Connect the BAT-100A battery. Then press and hold the
LEARN button (10) for approximately 8 s until the yellow LED
(12) starts flashing. Then release the button.
5. When flashing expires (2 x 7 flashes) the yellow LED
illuminates. This indicates that the siren is not enrolled.
Notes:
When a reset is done the yellow LED goes off and it means
that there is some control panel in the siren's radio range with
an open service mode and the enrollment procedure has been
performed again and the siren is assigned to that control
panel.
The siren supports wireless firmware update. It can be performed
by N-Link software in Service mode.
1. Go to N-Link: Control panel – Firmware update. In the
offered list the JA-16A RB should appear. If the N-Link SW
detects
the existence of newer firmware than that in the siren,
it is automatically checked (ticked) for upgrading.
2. Press the OK button to perform the update of the selected
devices.
3. When the update is finished, check the internal settings
of the siren on the Devices tab – Internal settings.
4. Test the siren's functions.
Notes:
The mini USB connector (7) serves for firmware upgrading
by a direct connection with the PC using a USB cable. This
way is recommended when a wireless upgrade was not
performed successfully.
Internal settings of the siren
The siren properties can be set in the Devices tab of the N-Link
software. When at the siren position, use the Internal settings option
to open a dialog window, internal setting is separated into 2 tabs: Setting
and Signalling PG (default settings are marked *):
Setting tab:
Acoustic indication of alarms from sections: to set for which
sections the siren should indicate an alarm, as well as setting
the chirps. The default setting is indication for all sections enabled.
Reaction: defines whether the siren should indicate EW* (external
warning) or IW (internal warning). Alarm indication can also be
disabled completely (other functions remain enabled).
Siren sound: intermittent*, continuous. Option intermittent saves
energy.
Maximum siren time: No, 1, 2, 3*, 4, 5 minutes, During an alarm.
Option 'No' – the siren doesn't indicate alarm acoustically (optical
indication remains). Option 'During an alarm – acoustic indication in
duration of 'Alarm length' set in 'Parameters'. Note: the maxim Alarm
length is 20 minutes, which would significantly affect the battery lifetime.
1 / 2
FW update
MNM55101

Advertisement

loading

Summary of Contents for jablotron JA-16A RB

  • Page 1 JA-16A RB Wireless outdoor battery-powered siren The JA-16A RB is a component of the JA-10 system. It is used for system alarm indication outside a building. It can also be used for supplementary acoustic signalling (PG activation, arming, chirps). The siren is powered by just one lithium battery with no other external power.
  • Page 2 Technical specifications During warning: YES/NO* - if enabled, the siren indicates by triple flashing: The JA-16A RB parts (lithium battery, front cover and base) are supplied individually. 1) inability to set (a system status which prevents setting, such Power Lithium battery 3.6 V/13 Ah type BAT-100A...