H3C S3610- 28P Installation Manual page 7

Table of Contents

Advertisement

Installation Manual
H3C S3610 Series Ethernet Switches
LED
DC-input power
LED
7-segment
numerical display
Mark
Status
Solid green
RPS
Solid yellow
OFF
In the process of
POST
POST failure
Unit
Loading software
Fan failure
1-4
Chapter 1 Product Overview
Meaning
The DC input and the AC
part are all normal.
The DC input is normal; the
AC part is abnormal or the
AC input is disconnected.
The DC input is
disconnected.
The number of current
POST item is displayed.
The number of the failed
POST item is displayed.
The short bars are lighted
one after another in
clockwise direction during
the loading.
"F" is displayed.

Advertisement

Table of Contents
loading

Table of Contents