Powering on and powering off the module

Powering on the module

Power-on methods

The switch module supports the following power-on methods.
Table 2 Switch module power-on methods
Power-on method
Together with the server
From the OM Web interface
From the OM CLI

Procedure

When power is present on the switch module, its health LED is steady green. For the health LED
location on the module, see "LEDs and buttons."
Powering on the switch module together with the server
If the switch module has been installed on the server before the server is powered on, it will
power on automatically when the chassis is powered on. You are not required to perform any
extra operations.
If you install the switch module on an operating server, it will power on automatically. You are
not required to perform any extra operations.
Powering on the switch module from the OM Web interface
1.
Obtain required information as described in
Table 3 Obtaining required information
Parameter
OM management IP
OM username and password
Slot where the switch module
resides
Data in this table is used as an example.
2.
Log in to the OM Web interface.
a. As shown by callout 1 in
management IP (in the format of https://OM_ip_address)
b. As shown by callout 2 in
Application scenario
The switch module is installed on the server before
the server is powered on.
The switch is installed on the server after the server is
powered on.
The switch module is installed on an operating server and
the module is powered off (the heath LED on the module is
off).
Table
3.
Setting
Management IP address (default): 192.168.100.100
Subnet mask (default): 255.255.255.0
Username (default): admin
Password (default): Password@_
1
Figure
1, open your browser on your PC and enter the OM Web
Figure
1, enter the username and password.