Step 5
SET SENSOR
Warning, by default there are no sensor configured.
The TEMPUS-AG-CT has a + S - sensor input on which you can connect a rain sensor or a flow meter/water meter or pressure switch after cutting the blue wire.
Once the sensor is connected, it is necessary to configure it in the application.
1. Using the MyToroTempus mobile app, connect to your TEMPUS-AG-CT via Bluetooth.
2. Click on Add Sensor.
3. Select your sensor type and follow the instructions given by the application
Rain Sensor
Step 5
SET FLOWMETER
1. Check the «Instant Value».
Instant Value: Ensures that the volume consumed indicated on the water meter is the same as the volume displayed on the application. If a gap is noted, check the
wiring (polarity) or adjust the «COEFFICIENT» value.
2. Fill in the remaining fields.
High threshold (daily volume): maximum consumption (in liter) that you do not want to exceed in a period of 24h. If the goal is exceeded you will be alerted
immediately (by e-mail and notification smartphone and / or tablet).
Low threshold (daily volume): minimum consumption (in liters) that you want to achieve over a period of 24h. If the goal is not reached you will be alerted the
next day at 7am (by e-mail and notification smartphone and / or tablet).
Leak alert volume: water volume threshold (in liter) from which you want to be alerted.
Station flow: for each station, read the flowmeter at time T (Cpt1), then at time
T + 5mn (Cpt2).
Make the calculation (Cpt2 - Cpt1) / 5 => Flow (L / min)
In the application fill in the results.
High Threshold (Station Flow Alerts): Maximum consumption warning threshold in % of the calibrated flow of the channel. The «High threshold» alert is
immediate as soon as it is reached.
Low threshold (Station Flow Alerts): Minimum consumption warning threshold in % of the calibrated flow of the channel. The «High threshold» alert is
immediate as soon as it is reached. For each station flow alert you have the possibility to define the desired type of action:
• No action: watering continues.
• Permanent OFF: resuming watering requires a manual ON command (in the application on the programmer concerned).
• Inhibit the output: stops the station concerned, requires the acknowledgment of the alert (in the application on the programmer concerned) to reactivate the
station.
Stabilization time:
Time required before the water flow is stable when starting and stopping the station. It eliminates the peak flow (start) or leak (stop). The time is the same for all
stations. During this period, the consumption is not taken into account for triggering alerts or actions.
l/mn
Flowmeter, water meter
Connect your + S - input to a water meter equipped with a flow sensor as shown above. Use dry contact flow sensors or equivalent. For polarized flow sensors,
when wiring,observe the polarization : Red wire -> + Black wire - > -