SUSPA GmbH Installation Instructions English SUSPA Movotec SMS (Controller Laing LTC-EU) Read installation instructions carefully before initial use! Follow the safety instructions! This partly completed machinery is intended to be incorporated into other machinery, other partly completed machinery/equipment or to be joined with another framework so as to form a complete ma- chine as specified under the Machinery Directive.
Page 2
The contents of the user information is the intellectual property of SUSPA GmbH. SUSPA GmbH expressly reserves the ownership of and copyright to the data contained in the user information. Reproduction and duplication, even in excerpts, are permitted only upon the written consent of SUSPA GmbH.
IMPORTANT Note cludes the danger of damage to property and the risk of injuries. Indicates certain safety-related instruc- SAFETY INSTRUCTION Safety instruction tions or procedures. Table 1 Signal words and signal colors SUSPA Movotec SMS - Installation Instructions Page 5...
Identification and Notes 2.3 Intended Use The SUSPA Movotec SMS (Spindle Motor System) is used to adjust the height of workplaces that are used when sitting or standing. The lifting elements are designed for compressive loads. IMPORTANT Please make sure that installation or start-up or the appropriate height adjustment has been selected.
Operating the system beyond the physical operating limits described in the Section "Oper- ating Conditions" ▪ Modifying the controller software without prior consultation with SUSPA GmbH ▪ Any modifications to the height adjustment system as well as any add-ons or conversions without prior consultation with the company, SUSPA GmbH ▪...
2.5 General Information 2.5.1 Warranty and Liability The "General Terms and Conditions" of SUSPA GmbH always apply. These are made available to the owner upon signing of the contract at the latest. Warranty claims and liability claims for personal injury and material damage are excluded if they are at- tributed to one or more of the following causes: ▪...
Increase the service life and reliability of the component ▪ To reduce the costs of production downtime IMPORTANT The right to technical modifications in the context of continuous product improvement is reserved at all times without prior notification! SUSPA Movotec SMS - Installation Instructions Page 11...
18 years of age ▪ who are physically and mentally suitable for this purpose Outside of the Federal Republic of Germany, the appropriate accident prevention regulations and safety regulations of the respective country apply. SUSPA Movotec SMS - Installation Instructions Page 12...
Page 13
Height Adjustment System. The external professional personnel conduct the transport up to the transfer to the operator. Private person A person who has no previous knowledge in the installation of mechanical and electrical components. SUSPA Movotec SMS - Installation Instructions Page 13...
Please note all warning and safety instructions in these installation instructions. The following circumstances could increase the hazard potential of the component: ▪ Danger posed to persons through mechanical influences ▪ Malfunctions that may impair the safety during operation of the component SUSPA Movotec SMS - Installation Instructions Page 14...
Applicable and binding accident-prevention regulations ▪ Applicable and binding regulations at the place of use ▪ Recognized technical regulations for safe and professional working methods ▪ Existing environmental protection regulations ▪ Other applicable regulations SUSPA Movotec SMS - Installation Instructions Page 15...
IP 42 in accordance with DIN EN 60529 Traversing cycles At least 5,000 cycles in compliance with maintenance Table 5 Technical Specifications IMPORTANT The noise emission level of the height adjustment system is considerably less than 70 dBA SUSPA Movotec SMS - Installation Instructions Page 16...
The following explains how the subsystems work together and make the raising and lowering of the Height Adjustment System possible. Figure 1 Electrical controller SMS LTC 384 Figure 3 UP/Down hand switch LM2LCDP Figure 4 Memory hand switch LD6LC (optional) Figure 2 Electrical lifting element SUSPA Movotec SMS - Installation Instructions Page 17...
Page 18
As soon as the operator presses the arrow keys (up or down) of the connected manual switch, the control- ler receives the signal to set the electro-mechanical drive of the lifting elements in motion. Depending on the direction of the arrow the motor moves the lifting elements up or down. SUSPA Movotec SMS - Installation Instructions Page 18...
/ weight. IMPORTANT The shipment must be made by professional personnel of SUSPA GmbH. The further transport must be made by professional personnel and private persons. The following points must be ob- served for transporting / unloading of the components: ...
Make sure that walls, furniture, electrical wiring, or other solid structures do not im- pede the movement of the workplace during operation. IMPORTANT The installation of the component must be carried out by professional personnel of SUSPA GmbH, other professional personnel, maintenance personnel and private persons. IMPORTANT Do not lift the Height Adjustment System on the motor cables or power cords.
Max + 40 °C Relative moisture: ▪ Max 80% at 32 °C, above that decreasing linearly to 50% at 40 °C Contamination: No heavy contamination due to dust, acids, corrosive gases Table 6 Operating conditions SUSPA Movotec SMS - Installation Instructions Page 21...
Page 22
In lx Index Ra Metal machining and processing, foundries and casting Assembly work: - Rough - Medium-fine - Fine - Very fine Table 7 Lighting requirements SUSPA Movotec SMS - Installation Instructions Page 22...
Attach the lifting elements vertically and parallel to each other, so that they do not block each other during lifting and lowering. SUSPA GmbH provides various brackets for reducing the holes to be drilled and facilitating the installation. Keep electrical cord away from sharp edges and moving parts.
Fasten the drill templates parallel to the surfaces of the legs of the workplace. Make sure that the drilling template is aligned correctly. IMPORTANT Make sure that the drill templates are illustrated in the inverted position based on the po- sitioning of the workplace. SUSPA Movotec SMS - Installation Instructions Page 24...
Page 25
The installation instructions for the lifting elements is located on the drilling templates that are delivered with the system. Drill four holes (ø 6 mm) at the locations indicated on the drilling templates. Figure 8 Drilling the holes SUSPA Movotec SMS - Installation Instructions Page 25...
Page 26
Position the workplace properly again such that the leveling feet stand on the floor. IMPORTANT Take care to ensure that the workplace is not put down too abruptly in order to avoid damaging the lifting elements. SUSPA Movotec SMS - Installation Instructions Page 26...
Page 27
Installation Figure 10 Dimensions of the lifting element SUSPA Movotec SMS - Installation Instructions Page 27...
This enables ease of working in case you need to do service work. Ensure that there is adequate air circulation during installation. There is, in fact, little heat developed by the controller, but nonetheless, it exists. SUSPA Movotec SMS - Installation Instructions Page 28...
In order to be able to detect such a change in inclination of the moving part of the table system, the SMS LTC384 electrical controller must be mounted directly on the moving table system (table top) or the table top frame. SUSPA Movotec SMS - Installation Instructions Page 30...
Page 31
The table user is solely responsible for ensuring that there is no personal injury or other damage when operating the table! SUSPA Movotec SMS - Installation Instructions Page 31...
When attaching, insert metal washers between the screws and the manual switch to pre- vent damage to the plastic housing. Figure 15 Attaching the Up/Down manual switch LM2LCDP Figure 16 Dimensions of the Up/Down manual switch LM2LCDP SUSPA Movotec SMS - Installation Instructions Page 32...
Page 33
Installation Figure 17 Attaching of the memory manual switch LD6LC Figure 18 Dimensions of the memory manual switch LD6LC SUSPA Movotec SMS - Installation Instructions Page 33...
No. 6) IMPORTANT The SUSPA Movotec SMS system can be supplied in different variants. The supply variants contain 1 to 8 lifting elements. There is a different controller variant depending on the supply variant. The correct variant of the controller can be supplied only if you specify the supply variant at the time of placing the order.
Page 35
Connect the power cables to the appropriate input of the electrical controller (Figure 19; connection No. 6) The complete assembly of this linking controller system with more than 4 lifting elements is shown at the next page in Figure 21 SUSPA Movotec SMS - Installation Instructions Page 35...
Page 36
After the power connectors have been connected, they must be coupled to the power source (Socket). Never connect the two controller power connectors separately to the power supply (Socket). SUSPA Movotec SMS - Installation Instructions Page 36...
Check the electrical lines and cables to ensure that they are fastened securely to the workplace and have not been damaged during the operation. Figure 22 Coiling of electric wires and cables SUSPA Movotec SMS - Installation Instructions Page 37...
18mm. Place a level on the surface of the work station. Ensure a very uniform load distribution when using several lifting elements. Figure 23 Adjusting the workstation with level SUSPA Movotec SMS - Installation Instructions Page 38...
Page 39
One indicator of a uniform load distribution during operation of the Height Adjustment System is that all the lifting elements in the area of drive units (motor / cable outlet) have the same tem- perature. SUSPA Movotec SMS - Installation Instructions Page 39...
Connect the workplace to the power supply only after checking the above-mentioned as- pects. Allow the controller to adjust to the change from cold to hot environments for a few hours before putting them into operation, otherwise condensed water may damage them. SUSPA Movotec SMS - Installation Instructions Page 40...
Height Adjustment System. Ensure adequate ventilation to ensure sufficient heat dissipation from the components of the Height Adjustment System and do not exceed the duty cycle. SUSPA Movotec SMS - Installation Instructions Page 41...
All functions of the Height Adjustment System can be controlled using the manual switch. Figure 25 Up /Down manual switch LM2LCDP Figure 26 Memory manual switch LD6LC (optional or necessary for a more than 4-leg system) SUSPA Movotec SMS - Installation Instructions Page 42...
• Now the workstation can be moved by using the two direction buttons on the manual switch. Table 8 Function of the Up /Down manual switch LM2LCDP SUSPA Movotec SMS - Installation Instructions Page 43...
4 times in quick succession The controller acknowledges this operation with one signal tone. Table 9 Function of the memory manual switch LD6LC SUSPA Movotec SMS - Installation Instructions Page 44...
Page 45
The memory position is retained even after a power failure. e.g. the memory position „1“ : Push the key „1“ 4 times in quick succession Repeat the described procedure to store new memory positions. SUSPA Movotec SMS - Installation Instructions Page 45...
If the reset is successful, the display shown the position „ 00 „. and the controller acknowledges this with a signal tone • Now the workstation can be moved by using the two direction buttons on the manual switch. SUSPA Movotec SMS - Installation Instructions Page 46...
IMPORTANT Do not disassemble the system components (i.e. lifting elements, electrical controller, switch) unless authorized by SUSPA GmbH. Any attempt to repair the system or the system components without the authorization of SUSPA GmbH will void the warranty. 7.6 Programming new Upper and Lower Limit Setting new upper and lower height limitations.
Reaching the limit adjustment menu will be confirmed by two sounds Step 4 • Delete the upper limit (user height) • Press „UP“ button 1 time to delete the current upper limit • Successful storage will be confirmed by one sound SUSPA Movotec SMS - Installation Instructions Page 48...
• Reaching the limit adjustment menu will be confirmed by two sounds Step 4 • Setting the new upper limit (user height) • Press „UP“ button 1 time for setting the new upper limit • Successful storage will be confirmed by two sounds SUSPA Movotec SMS - Installation Instructions Page 49...
Reaching the limit adjustment menu will be confirmed by two sounds Step 4 • Delete the lower limit (user height) • Press „DOWN“ button 1 time to delete the current lower limit • Successful storage will be confirmed by one sound SUSPA Movotec SMS - Installation Instructions Page 50...
In this case when pushing the appropriate arrow key to save the new limit the follow- ing short beeps can be heard, indicating that the new limit was not saved. In this case the distance between the upper and lower limit must be increased. SUSPA Movotec SMS - Installation Instructions Page 51...
• Delete the upper limit (user height) • Press memory key „1“ shortly 1 time to confirm the deletion • Successful deletion will be confirmed by one sound SUSPA Movotec SMS - Installation Instructions Page 52...
• Setting the new upper stroke limit (user height) • Press memory key „1“ shortly 1 time to store the selected limit • Successful storage will be confirmed by one sound SUSPA Movotec SMS - Installation Instructions Page 53...
• Delete the lower limit (user height) • Press memory key „1“ shortly 1 time to confirm the deletion • Successful deletion will be confirmed by one sound SUSPA Movotec SMS - Installation Instructions Page 54...
In this case when pushing the appropriate arrow key to save the new limit the follow- ing short beeps can be heard, indicating that the new limit was not saved. In this case the distance between the upper and lower limit must be increased. SUSPA Movotec SMS - Installation Instructions Page 55...
Sudden power supply outage for the lifting system Details and particulars regarding occurring errors and the rectification thereof can be found in the instruc- tion manual of the electrical controller: https://laing-controller.de/en/downloads SUSPA Movotec SMS - Installation Instructions Page 56...
(I t) supplied by the LED blinking for a complete cool back, around 13 minutes are re- controller quired short long short long => Reset error by pressing any key SUSPA Movotec SMS - Installation Instructions Page 57...
Page 58
2,3,4. There must be no gap One of the two Hall sensors Check Hall sensors and cables is not giving a signal Table 10 Error codes Memory manual switch or LED blinking sequences controller SUSPA Movotec SMS - Installation Instructions Page 58...
Manual switches, motors or power plugs are not correctly connected to the controller. Indicator: Diverse symptoms Solution: Check the correct connection of the components, make sure that all connectors are firmly plugged into the corresponding sockets! SUSPA Movotec SMS - Installation Instructions Page 59...
Verify system load does not exceed rating and remove weight as needed. Striking of an object when Remove the object. raising or lowering (e.g. a trashcan etc.) Table 11 Troubleshooting: System does not operate SUSPA Movotec SMS - Installation Instructions Page 60...
Page 61
Check the load on the table if the fault persists. ▪ Initialize the controller once more. ▪ Notify your service partner if the controller is still not working. Table 12 Troubleshooting SUSPA Movotec SMS - Installation Instructions Page 61...
Perform a functional test (test run) after maintenance or repair work. Check the proper function of all safety and protective devices. Remove any used tools, screws, aids or other objects from the operational area of the Height Adjustment System. SUSPA Movotec SMS - Installation Instructions Page 62...
In addition, the maintenance instructions of the manufacturers of outsourced parts must be observed and followed! SUSPA Movotec SMS - Installation Instructions Page 63...
8.3.3 Damages to Electrical Wires Check the insulation of the electrical wires for visible signs of aging and wear. Replace defective or dam- aged wiring. SUSPA Movotec SMS - Installation Instructions Page 64...
This includes lub- ricants, plastics and batteries etc. Have the machine disposed of properly by an authorized specialist company on account of the potential risk of environmental pollution. SUSPA Movotec SMS - Installation Instructions Page 65...
Year of construction: 2023 Designated use: The SUSPA Movotec SMS LTC (EU-Version) is used for height adjustment of sitting or standing workstations or work tables the delivered version is compliant with Directive 2006/42/EC of the European Parliament and of the...