Symbols Explained; Caution; Specification - ProBreeze PB-AC04 Instruction Manual

7000 btu portable air conditioner
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
appliance from being pulled down.
Do not pull on the power cord. Never
move, carry, or hang the appliance by
the power cord.
Do not move the appliance whilst it is
in use.
BATTERIES
This product is supplied with AAA disposable
batteries.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
BATTERY WARNING: KEEP OUT OF
REACH OF CHILDREN.
Choking hazard. Do not swallow. Harmful if
swallowed. Swallowing can lead to chemical
burns, perforation of soft tissue, and death.
Severe burns can occur within 2 hours of
ingestion. If you think batteries might have
been swallowed or placed inside any part of
the body, seek immediate medical attention.
This product only uses a AAA battery.
It is not compatible with other battery
types.
Do not allow children to handle
batteries.
If the battery compartment does not
close securely, stop using the product
and keep it away from children.
Ensure that the battery is installed with
the correct polarity (+ and –).
Remove exhausted battery promptly.
Always inspect new batteries before
use. Damaged or weak batteries may
leak acid. Discontinue use if batteries
show signs of leakage, damage, or
weakness at any time.
Ensure the battery compartment is
correctly and securely closed after
installing the batteries.
Wash hands after handling batteries.
Disposable batteries are not rechargeable
and must be recycled or disposed
06 | English
of separately from household waste.
Always dispose of batteries at an official
collection point and according to your
local environmental laws and guidelines.
SAFETY WARNING
WARNING: THE APPLIANCE MUST BE
INSTALLED, OPERATED AND STORED
IN A ROOM WITH A FLOOR AREA
LARGER THAN 7M2.
This appliance contains 0.13kg (130g) of
R290 refrigerant gas.
R290 is a refrigerant gas that complies
with the European directive on the
environment.
Do not puncture any part of refrigerant
circuit.
Be aware R290 refrigerant is odourless
and does not have the odour normally
associated with natural gas and propane
tanks.
Do not use means to accelerate the
defrosting process or to clean, other
than those recommended by the
manufacturer.
The appliance must be placed in an
area without any continuous sources
of ignition such as open flames, gas, or
electrical appliances in operation.
Do not puncture and do not burn.
If the appliance is installed, operated
or stored in a non-ventilated area, the
room must be designed to prevent
the accumulation of refrigerant leaks
resulting in a risk of fire or explosion due
to ignition of the refrigerant caused by
electric heaters, stoves, or other sources
of ignition.
The appliance must be stored in such a
way as to prevent mechanical failure.
Individuals who operate or work on
the refrigerant circuit must have the
appropriate certification issued by an
accredited organisation that ensures
competence in handling refrigerants
according to a specific evaluation
recognised by associations in the
industry.
Maintenance and repairs that require
the assistance of other qualified
personnel must be performed under the
supervision of an individual specified in
the use of flammable refrigerants.

SYMBOLS EXPLAINED

― ―
Equipment complies with the
applicable EU safety requirements
and regulations.
Equipment complies with the
applicable UK safety requirements
and regulations.
Please read instruction manual and
retain for future use.
For indoor use only.

CAUTION

Do not operate the appliance if the
room temperature is greater than 32°C
in cooling mode or lower than 5°C in
dehumidifying mode.

SPECIFICATION

Model: PB-AC04
Product Dimensions: 31.5x31x70cm
Net Weight: 20kg
Input Voltage: 220-240V~
Frequency: 50Hz
Cooling Capacity: 7000 BTU/h
Refrigerant: R290 (130g)
Energy Efficiency Class: A
Rated Capacity for Cooling: 2051W
Rated input – Cooling: 780W
Rated Current – Cooling: 3.5A
EER For Cooling: 2.6
Moisture Removal: 0.8L/H
Air Flow Volume: 290m3/H
Applicable Area: 8 – 16m
2
Operating Temperature Range: 5-35°C
Available Temperature Settings: 16-32°C
Noise Level: 54dBA