Maintenance
7.6

Pneumatic system

Risk of injury!
Activities on compressed−air systems may only be carried out by trained personnel
with special knowledge and experience in this area.
Prior to replacing pneumatic parts close down the compressed air supply.
7.6.1
Air−conditioning unit
OPERATION
METHOD
Activate
Turn valve (3) in direction of flow
compressed air
(clockwise), see position shown.
or
switch off
Turn valve (3) cross in relation to the
direction of flow (counter−clockwise).
Option: main shut−off valve (1).
Set the
Read manometer (5).
compressed air
Pull setting knob (2) up out of the
pressure
locking and turn until the manometer
reads 5".
Lock setting knob (2) by pushing it
down.
Drain reservoir
Is automatically drained or when the
(6)
compressed air is switched off.
Clean reservoir
Switch off compressed air.
(6) and sinter
Loosen reservoir (6).
ing−bronze
Dismount filter cartridge.
filter cartridge
Clean the cartridge exclusively with
paraffin, water or dry−cleaning
naphtha. Replace filter cartridge when
heavily contaminated.
Blow dry from the inside to the outside.
Mount in reverse order.
Switch on compressed air.
REMARKS
Attention: always turn the valve (3)
fully into the end positions. Do not let
it stand in an intermediate position.
The pneumatic system is vented.
The compressed air is switched off
when the Emergency−Off button (S1)
is pressed.
With machine standing still.
Manual draining is possible by turning
the screw (4) counter−clockwise.
See manual in section 8.
Do not use agents containing
trichloroethylene, such as benzene,
acetone and other liquids with
softeners.
Bosch Verpackungstechnik
PAGE 11
T7.6