Space-Ray SWH Installation Manual

Space-Ray SWH Installation Manual

Lphw warm air heater

Advertisement

Quick Links

®
INSTALLATION MANUAL
LPHW Warm Air Heater
Model SWH

Advertisement

Table of Contents
loading

Summary of Contents for Space-Ray SWH

  • Page 1 ® INSTALLATION MANUAL LPHW Warm Air Heater Model SWH...
  • Page 2: Table Of Contents

    Content General Description Function Matching capacity of hot water boiler and SWH Guarantee Technical Technical data Dimensions Operating parameters Pre-check Installation Suspension Water connections Electrical connection 230Vac Supply General functioning of the unit Connecting options 4.3.1 Connection with only a room thermostat 4.3.2 Connection with room thermostat combined with contact thermostat...
  • Page 3: General

    In case the capacity of the boiler is higher than that of exchanger consist of copper tubes and aluminium fins. the SWH, the boiler won’t be able to release all the heat This is an approved design for an optimal heat exchange.
  • Page 4: Dimensions

    3. Installation Working pressure: Max. 5 bar 3.1 Suspension Water temperature: Max. 100⁰C The SWH is provided with 8 No M10 suspension points Min. 4⁰C (risk of freezing) on the side panels. Ambient temperature: Max. 40⁰C Min. 4⁰C (risk of freezing)
  • Page 5: Water Connections

    4.2 General functioning of the unit The SWH is simply described as a radiator with a fan at the rear. If there is hot water flowing through the radiator, and the heater is on, the heater will blow warm air.
  • Page 6: Connection With Room Thermostat Combined With Contact Thermostat

    (disconnect) causing the SWH fan to stop. The on/off room thermostat will operate the fan of the SWH when there is a demand for heat. The fan will blow air over the heat exchanger, if the water is hot the heater will discharge warm air.
  • Page 7: Maintenance And Operation

    Contact thermostat vacuum cleaner or compressed air taking care to avoid- will supply power to the SWH. The fan will op- void damaging the heat exchanger fins. erate. If an optional 5 speed switch has been Clean also the fan, guard and air outlet grille.
  • Page 8: Example

    6.1 Example What is the output of a SWH 230 with a water supply temperature of 80/60 °C, with an air temperature of 10°C with the 5 speed switch is set to 3? Look in the SWH 230 performance sheet, select 80/60°C water temp and the row for air temp 10°C.
  • Page 9: Performance Table Swh 110

    6.2.1 Perfomance table SWH 110...
  • Page 10: Performance Table Swh 115

    6.2.2 Perfomance table SWH 115...
  • Page 11: Performance Table Swh 120

    6.2.3 Perfomance table SWH 120...
  • Page 12: Performance Table Swh 230

    6.2.4 Perfomance table SWH 230...
  • Page 13: Performance Table Swh 235

    6.2.5 Perfomance table SWH 235...
  • Page 14: Performance Table Swh 245

    6.2.6 Perfomance table SWH 245...
  • Page 15: Performance Table Swh 350

    6.2.7 Perfomance table SWH 350...
  • Page 16: Performance Table Swh 365

    6.2.8 Perfomance table SWH 365...
  • Page 17: Performance Table Swh 380

    6.2.9 Perfomance table SWH 380...
  • Page 18 ® Tel: +44(0)1473 830 551 Fax: +44(0)1473 832055 www.spaceray.co.uk info@spaceray.co.uk Gas Fired Products (UK) Ltd Chapel Lane Claydon Ipswich Suffolk, IP6 0JL FACTORIES: IPSWICH, ENGLAND - CHARLOTTE, N.C, U.S.A SWH Manual Mar 23...

Table of Contents