Parking Lot Sensor | PLS
The sensor can be screwed into the base after the adhesive has cured. Before the insertion, use an air-blower to clean
the base of any residual dust. To simplify insertion, the arrow on the bottom of the sensor points towards the Bosch
logo (see Figure 10 Installing/screwing in the sensor). The sensor should be completely screwed in to ensure optimum
teaching of the sensor. To tighten it, use the T20 screw and a T20 screwdriver and tightening torque of 1,8 to 2,2 Nm.
Close the opening with the sensor sealing cap afterward.
Bottom part of the
sensor core
First, push the sensor core on the logo side and ensure that the sealing O
ring part is well compressed on this sensor base side.
Then, tilt the sensor core against the base until the sealing O ring is
completely compressed on the sensor base.
Figure 10 Installing the sensor - method
© Robert Bosch France SAS 2022. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the
event of application for industrial property rights. Data subject to change without notice. Printed in France, December 2022.
Align the mark as shown above.