11.
After modifying the parameters:
To apply the changes to the selected trunk only, click the Apply Trunk Settings button.
To apply the changes to all the trunks, click the Apply to all Trunks button.
The screen is refreshed, parameters become read-only (indicated by being grayed). The
Stop Trunk button appears at the bottom of the screen.
12.
Access the 'TDM Bus Settings' screen (Advanced Configuration>TDM Bus Settings). In
the 'PCM Law Select' field, select 'A-law' for E1 trunks and 'μ-Law' for T1 trunks.
13.
To save the changes so they are available after a power fail, click the Save Configuration
button on the main menu bar; the 'Save Configuration to the Flash Memory' screen is
displayed. Click the Save Configuration button in the middle of the screen; a confirmation
message appears when the save is complete.
For more detailed information on configuring the MG 3200 trunk settings, refer to the MG 3200
User's Manual, document # LTRT-727xx.