Start-Up Checklist - Carrier FAS150 Installation, Start-Up And Service Instructions Manual

Packaged air-handling units with r-410a refrigerant 60 hz
Table of Contents

Advertisement

NOTE: To avoid injury to personnel and damage to equipment or
property when completing the procedures listed in this start-up check-
list, use good judgment, follow safe practices, and adhere to the safety
considerations/information as outlined in preceding sections of this
Installation, Start-Up, and Service document.
I. PRELIMINARY INFORMATION
OUTDOOR: MODEL NO. _________________________
SERIAL NO._______________________________
ADDITIONAL ACCESSORIES _______________________________________________________________________
II. PRE-START-UP
OUTDOOR UNIT
IS THERE ANY SHIPPING DAMAGE?
IF SO, WHERE:____________________________________________________________________________________
_________________________________________________________________________________________________
WILL THIS DAMAGE PREVENT UNIT START-UP?
CHECK POWER SUPPLY. DOES IT AGREE WITH UNIT?
HAS THE GROUND WIRE BEEN CONNECTED?
VERIFY GROUND INTEGRITY WITH CONTINUITY TEST.
HAS THE CIRCUIT PROTECTION BEEN SIZED AND INSTALLED PROPERLY?
ARE THE POWER WIRES TO THE UNIT SIZED AND INSTALLED PROPERLY?
HAVE COMPRESSOR HOLDDOWN BOLTS BEEN LOOSENED?
CONTROLS
ARE THERMOSTAT(S) AND INDOOR FAN CONTROL WIRING CONNECTIONS MADE AND
CHECKED?
ARE ALL WIRING TERMINALS (including main power supply) TIGHT?
HAVE OUTDOOR UNIT CRANKCASE HEATERS BEEN ENERGIZED FOR 24 HOURS?
INDOOR UNIT
HAS WATER BEEN PLACED IN DRAIN PAN TO CONFIRM PROPER DRAINAGE?
ARE PROPER AIR FILTERS IN PLACE?
HAVE FAN AND MOTOR PULLEYS BEEN CHECKED FOR PROPER ALIGNMENT?
DO THE FAN BELTS HAVE PROPER TENSION?
PIPING
FAS/FHS
HAS FOAM SHIPPING BLOCK BEEN REMOVED FROM THE TXV (Thermostatic Expansion Valve)?
ARE LIQUID LINE SOLENOID VALVES LOCATED AT THE INDOOR UNIT (FAS/FHS) OR
OUTDOOR UNIT (CAS/CHS) COILS AS REQUIRED?
HAVE LEAK CHECKS BEEN MADE AT COMPRESSORS, CONDENSERS, INDOOR COILS,
TXVs (Thermostatic Expansion Valves) SOLENOID VALVES, FILTER DRIERS, AND FUSIBLE PLUGS
WITH A LEAK DETECTOR?
LOCATE, REPAIR, AND REPORT ANY LEAKS.
HAVE ALL COMPRESSOR SERVICE VALVES BEEN FULLY OPENED (BACKSEATED)?
ARE THE COMPRESSOR OIL SIGHT GLASSES SHOWING CORRECT LEVELS?
FASFHS150-180-01SI

START-UP CHECKLIST

(SPLIT SYSTEMS WITH FAS/FHS UNITS)
Specifications are subject to change without notice.
INDOOR: MODEL NO. ______________________
SERIAL NO. ______________________________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)___________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
(Y/N)_________
______________
(Y/N)_________
(Y/N)_________
CL-1