LG MULTI V ARNH423K3A4 Installation Manual page 87

Hydro kit high temperature (k3)
Table of Contents

Advertisement

Table 33: High Temperature Hydro Kit User Functions, continued.
Function
Tank Setting 1
Tank Setting 2
DHW Time Setting
Pump Frequency Setting
(g/min. [l/min.])
TH On / Off Variable,
Heating Air
TH On / Off Variable,
Heating Water
TH On / Off Variable,
Cooling Air
TH On / Off Variable,
Cooling Water
TH On / Off Variable, DHW
Heating Temp. Setting
Cooling Temp. Setting
Pump Setting in Heating
Pump Setting in Cooling
Forced Operation
CN_CC
Data Logging
Password Initialization
IDU Address Verification
* Deadband is the difference between the upper and lower limit setpoints.
Range
N / A
N / A
N / A
• 00: Perform hot water
• 01: Perform floor heating
• Operation Holding Time: 5 min.~ 95 min.
(Default: 30 min.)
• Stop Holding Time: 0 min.~600 min. (De-
fault: 30 min.)
N / A
Type: 0, 1, 2, 3 (Default: 0)
Type: 0, 1, 2, 3 (Default: 0)
N / A
N / A
Type: 0, 1, 2, 3 (Default: 0)
• 00: Outlet / Leaving (Default)
• 01: Inlet / Entering
N / A
• Type: Time, Always (Default: Always)
• OFF Time: 1 min.~60 min. (Default: 1 min.)
• ON Time: 1 min.~60 min. (Default: 2 min.)
N / A
• Value 1: ON, OFF (Default: On)
• Value 2 Forced Period: 20~180 hr, (Default:
20 hr.)
• Value 3 Pump Operating Time: 1~10 min.
(Default: 10 min.)
• D/C (Dry Contact) Automatic (Default)
• D/C (Dry Contact) Not installed
• D/C (Dry Contact) Installed
N / A
N / A
N / A
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG Life's Good" is a registered trademark of LG Corp.
PRE-STARTUP
Description
N / A for High Temperature Hydro Kit.
N / A for High Temperature Hydro Kit.
N / A for High Temperature Hydro Kit.
Sets heating demand priority.
Sets the hot water maintenance / suppression time.
N / A for High Temperature Hydro Kit.
The temperature of the heating air can be adjusted according to
the field environment preparing for heating claims.
The temperature of the heating water can be adjusted according
to the field environment preparing for heating claims.
N / A for High Temperature Hydro Kit.
N / A for High Temperature Hydro Kit.
Set the step value to adjust the hot water temperature thermal
on / off according to the field environment.
Sets the water pipe temperature control standard for heating
in accordance with the field environment.
N / A for High Temperature Hydro Kit.
Sets water pump operation / delay time option for heating.
N / A for High Temperature Hydro Kit.
Deactivates the logic that drives the water pump itself.
Must be set correct depending on optional dry contact.
Displays the error history of the connected Hydro Kit.
If the user setting password is forgotten, it can be initialized in the
installer settings.
Checks the result of the outdoor unit Auto Addressing using the
remote controller.