Download Print this page
LG ARNU09GVEA1 Owner's Manual
LG ARNU09GVEA1 Owner's Manual

LG ARNU09GVEA1 Owner's Manual

Arnu,lrnu-gve series heat pump indoor unit
Hide thumbs Also See for ARNU09GVEA1:

Advertisement

Quick Links

Models: ARNU,LRNU-GVE Series
Type: Convertible
IMPORTANT
• Please read this owner's manual carefully and thoroughly
before installing and operating your room air conditioner.
• Please retain this owner's manual for future reference after
reading it thoroughly.
LG
Prior to installation, this air-
conditioning unit must be
submitted for approval by the
utility service which provides
electricity (EN 61000-2,
EN 61000-3 Norm).
OPERATING TEMPERATURE( C)
COOLING MODE
INDOOR
MAX.
MIN.
MAX.
32 C
21 C
43 C
HEATING MODE
INDOOR
MAX.
MIN.
MAX.
27 C
20 C
24 C
OUTDOOR
MIN.
21 C
OUTDOOR
MIN.
1 C

Advertisement

loading

Summary of Contents for LG ARNU09GVEA1

  • Page 1 Models: ARNU,LRNU-GVE Series Type: Convertible Prior to installation, this air- conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-2, EN 61000-3 Norm). OPERATING TEMPERATURE( C) INDOOR MAX. 32 C INDOOR MAX. 27 C IMPORTANT •...
  • Page 2: Table Of Contents

    Convertible Type Indoor Unit Owner’s Manual TABLE OF CONTENTS Safety Precautions...3 Prior to Operation ...8 Operating Instructions...9 Name and Function of Remote Controller ...9 Maintenance and Service ...11 Before you Call for Service...13 Indoor Unit FOR YOUR RECORDS Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit.
  • Page 3: Safety Precautions

    Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING This symbol indicates the possibility of death or serious injury.
  • Page 4 Safety Precautions Do not modify or extend the power cable. • There is risk of fire or electric shock. For installation, always contact the dealer or an Authorized Service Center. • There is risk of fire, electric shock, explosion, or injury. Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
  • Page 5 Do not allow water to run into electric parts. • It may cause There is risk of fire, failure of the product, or electric shock. When flammable gas leaks, turn off the gas and open a window for ventilation before turn the product on. •...
  • Page 6 Safety Precautions When the product is not be used for a long time, disconnect the power supply plug or turn off the breaker. • There is risk of product damage or failure, or unintended operation. Installation Always check for gas (refrigerant) leakage after installation or repair of product.
  • Page 7 Do not block the inlet or outlet of air flow. • It may cause product failure. Do not step on or put anyting on the product. (outdoor units) • There is risk of personal injury and failure of product. Do not drink the water drained from the product.
  • Page 8: Prior To Operation

    Prior to operation Prior to Operation Preparing for operation 1. Contact an installation specialist for installation. 2. Use a dedicated circuit. Usage 1. Being exposed to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
  • Page 9: Operating Instructions

    Operating Instructions Name and Function of Remote Controller (Optional) AUTO SWING OPERATION SET TEMP Room Temp Time 2ndF Timer Operation unit No Func Program set Set no. Time Timer Cancel 2ndF Program Week Holiday PLASMA Set/Clr RESET Hour • Remote Controller Model Standard Type : PQRCUCA0 Simple Type : PCRCUSZ0...
  • Page 10 Operating Instructions Wireless Remote Controller (optional) This air-conditioner is equipped with wired remote controller basically. But if you want to be available with wireless remote controller, you pay for it. Signal transmitter CANCEL AUTO CLEAN Operation Mode Cooling Operation Auto Operation Healthy Dehumidification Operation Heating Operation •...
  • Page 11: Maintenance And Service

    Maintenance and Service Before performing any maintenance, turn off the main power to the system. Indoor Unit Grille, Case, and Remote Control Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives. NOTICE : Supply power must be disconnected before cleaning the indoor unit.
  • Page 12: Helpful Information

    Maintenance and Service When the air conditioner is not going to be used for a long time. When it is not going to be used for a long time. Operate the air conditioner on Air circulation mode for 2 to 3 hours. •...
  • Page 13: Before You Call For Service

    Before you call for service... Troubleshooting Tips! Save time and money! Check the following points before requesting repairs or service... If the malfunction persists, please contact your dealer. The air conditioner The room has a does not operate. peculiar odor. •...
  • Page 14 Memo Indoor Unit...