AEMC OX 5042B Quick Start Manual

AEMC OX 5042B Quick Start Manual

Handscope harmonic analyzer

Advertisement

Quick Links

Quick Start Guide
ENGLISH
Handscope Harmonic Analyzer
Oscilloscope
Model OX 5042B
PORTABLE OSCILLOSCOPES
WITH AEMC
INSTRUMENTS
®

Advertisement

Table of Contents
loading

Summary of Contents for AEMC OX 5042B

  • Page 1 Quick Start Guide ENGLISH Handscope Harmonic Analyzer Oscilloscope Model OX 5042B PORTABLE OSCILLOSCOPES WITH AEMC INSTRUMENTS ®...
  • Page 2 Copyright Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All rights reserved. © ® ® No part of this documentation may be reproduced in any form or by any means (including electronic storage and retrieval or translation into any other language) without prior agreement and written consent from Chauvin Arnoux , Inc., as governed by United States and International copyright laws.
  • Page 3: Statement Of Compliance

    Statement of Compliance Chauvin Arnoux , Inc. d.b.a. AEMC Instruments ® ® certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications.
  • Page 4 Cat. #2153.78 Cat. #2140.63 OX 5022B / OX 5042B Also Included: Cable - Replacement USB Charging Cable (1) Test Report Cat. #5100.17 (1) Battery Information Sheet (6) 1.2 V NiMH rechargeable batteries 2700 mA·h Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 5 OX 5022B / OX 5042B Cat. #2132.59 MF3000-24-1-1 Cable - Replacement USB Cat. #2132.63 Charging Cable Cat. #5100.17 Also Included: (1) Test Report (1) Battery Information Sheet (6) 1.2 V NiMH rechargeable batteries 2700 mA·h Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 6 OX 5022B / OX 5042B Cat. #2132.60 MF3000-14-1-1 Cable - Replacement USB Cat. #2132.60 Charging Cable Cat. #5100.17 Also Included: (1) Test Report (1) Battery Information Sheet (6) 1.2 V NiMH rechargeable batteries 2700 mA·h Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 7 Example: hardwired equipment in fixed installation and circuit breakers. CAT II corresponds to measurements performed on circuits directly con- nected to the electrical distribution system. Example: measurements on household appliances and portable tools. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 8: Precautions For Use

    Before the first use, start by fully charging the battery. NOTE: The batteries automatically begin recharging when the Oscilloscope is powered off, but connected to an external power supply. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 9 The main command functions are accessible using the buttons on the front panel. A graphic interface is used to: adjust the parameters related to the selected button ■ navigate using a horizontal main menu showing the current settings and ■ vertical sub-menus Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 10: Channel Isolation

    600 V CAT III reduces the operating range to the lower voltages and/or categories. The oscilloscope is rated 600 V CAT III; at least 600 V CAT III accessories must be used. Measurement Terminals Input Channel B External Input power Channel A supply Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 11: Control Features

    Adjustment of values in the secondary menus ■ Horizontal movement in a dialog box ENTER ■ Opens a dialog box from a main menu or a secondary menu ■ Validation of the items in a dialog box Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 12 Displays the main “Trigger” menu ■ Displays the main “Tools” menu ■ Displays the main “Acquisition” menu ■ Displays the main “Memory” menu ■ Displays the main “Measurement/Cursor” menu ■ Displays the “Help” window Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 13 For the best response, you must adjust the probe’s low-frequency compensation. NOTE: To carry out this adjustment, the two channels of your oscilloscope must be disconnected from the measured circuits before opening the battery housing cover. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 14 Turn the screw in either direction until the signal is horizontal and looks like the screen to the left. Your probe is now calibrated. Turn the BNC base again to close access to the adjustment screw and replace the battery cover. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 15: Remote Programming

    (603) 742-2346 repair@aemc.com E-mail: (Or contact your authorized distributor.) Contact us for the costs for repair, standard calibration, and calibration traceable to N.I.S.T. NOTE: You must obtain a CSA# before returning any instrument. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 16: Technical Assistance

    The instrument is warrantied to the owner for a period of two years from the date of original purchase against defects in manufacture. date of original purchase against defects in manufacture. This limited warranty is given by AEMC ® Instruments, not by the distributor from whom it was purchased. This warranty...
  • Page 17: Warranty Repairs

    Phone: (800) 945-2362 (Ext. 360) / (603) 749-6434 (Ext. 360) Fax: (603) 742-2346 repair@aemc.com E-mail: Caution: To protect yourself against in-transit loss, we recommend that you insure your returned material. NOTE: You must obtain a CSA# before returning any instrument. Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 18 NOTES: Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 19 NOTES: Handscope Harmonic Analyzer Oscilloscope Model OX 5042B...
  • Page 20 03/23 99-MAN 100587 V00 AEMC Instruments ® 15 Faraday Drive • Dover, NH 03820 USA Phone: (603) 749-6434 • (800) 343-1391 • Fax: (603) 742-2346 www.aemc.com © Chauvin Arnoux , Inc. d.b.a. AEMC Instruments. All Rights Reserved. ® ®...

Table of Contents