Upkeep and maintenance

The PS598-1 has a service panel, behind which there is a removable air filter. The air filter can be
replaced during operation.
Procedure
1. Open the service panel.
2. Take the air filter out of the device.
3. Clean the air filter.
4. Place the cleaned air filter in the device again.
5. Close the panel.
Power supply unit PS598-1 for SCALANCE XR-500
Compact Operating Instructions, 02/2023, A5E03275848-05
NOTICE
A badly contaminated air filter reduces air flow and can cause the device to be damaged.
Check the degree of contamination of the air filter regularly and clean it when necessary.