  • Page 1 FP120-Z1 Power supply kit A (70 W) Technical Manual Building Technologies A6V10393194_d_en_-- 2018-11-05 Control Products and Systems...
  • Page 2 Issued by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724-2424 www.siemens.com/buildingtechnologies Edition: 2018-11-05 Document ID: A6V10393194_d_en_-- © Siemens Switzerland Ltd, 2014 2 | 32 Building Technologies A6V10393194_d_en_-- Fire Safety 2018-11-05...
  • Page 3: Table Of Contents

    Table of contents About this document ................5 Applicable documents ................. 6 Download center ..................7 Revision history ..................7 Safety ....................8 Safety instructions ..................8 Safety regulations for the method of operation ..........9 Standards and directives complied with............11 Release Notes ...................12 Structure and function .................
  • Page 4 4 | 32 Building Technologies A6V10393194_d_en_-- Fire Safety 2018-11-05...
  • Page 5: About This Document

    Scope The information contained in this document is valid for FP120-Z1 power supply kit A (70 W). Intended use This standalone power supply is intended for decentralized supply to external devices.
  • Page 6: Applicable Documents

    1.1 Applicable documents Document ID Title A6V10393173 FP120-Z1 power supply kit A (70 W) – Mounting A6V10416448 FP120-Z1 power supply kit A (70 W) – Data sheet A6V10411051 FP2015-A1 power supply (70 W) – Technical manual 6 | 32 Building Technologies A6V10393194_d_en_--...
  • Page 7: Download Center

    You can download various types of documents, such as data sheets, installation instructions, and license texts via the following Internet address: http://siemens.com/bt/download Enter the document ID in the 'Find by keyword' input box. You will also find information about search variants and links to mobile applications (apps) for various systems on the home page.
  • Page 8: Safety

    Safety Safety instructions 2 Safety 2.1 Safety instructions The safety notices must be observed in order to protect people and property. The safety notices in this document contain the following elements: ● Symbol for danger ● Signal word ● Nature and origin of the danger ●...
  • Page 9: Safety Regulations For The Method Of Operation

    2.2 Safety regulations for the method of operation National standards, regulations and legislation Siemens products are developed and produced in compliance with the relevant European and international safety standards. Should additional national or local safety standards or legislation concerning the planning, mounting, installation,...
  • Page 10 Modifications to the system design and the products Modifications to the system and to individual products may lead to faults, malfunctioning and safety risks. Written confirmation must be obtained from Siemens and the corresponding safety bodies for modifications or additions. 10 | 32 Building Technologies...
  • Page 11: Standards And Directives Complied With

    ● Personal injury or damage to property caused by poor maintenance or lack of maintenance 2.3 Standards and directives complied with A list of the standards and directives complied with is available from your Siemens contact. 11 | 32 A6V10393194_d_en_--...
  • Page 12: Release Notes

    Safety Release Notes 2.4 Release Notes Limitations to the configuration or use of devices in a fire detection installation with a particular firmware version are possible. WARNING Limited or non-existent fire detection Personal injury and damage to property in the event of a fire. ●...
  • Page 13: Structure And Function

    Structure and function Release Notes 3 Structure and function Figure 1: Installation situation FP120-Z1 LED function display Connection card FP120-Z1 mainboard Battery U-rail TS35, 122 mm long Housing Installation positions for input/output modules and relay modules Power supply (70 W)
  • Page 14: Fault' Signal Transfer Relay

    Structure and function 'Fault' signal transfer relay 3.1 'Fault' signal transfer relay The power supply has two relays with changeover contact for the 'Fault' signal transfer. Contact Normal operation Fault MAINS Relay is activated. Relay is deactivated. NC contact is open. NC contact is closed.
  • Page 15: Mounting

    Scope of delivery The power supply kit (70 W) is supplied mounted with housing, a left-hand installation frame with integrated power supply (70 W) FP2015 and FP120-Z1 mainboard, a right-hand installation frame for optional components, and a pre- wired connection for the battery, as well as mounting instructions for wall mounting and optional components: Document ID A6V10393173.
  • Page 16: Mounting The Optional Components

    Mounting Mounting the optional components 4.2 Mounting the optional components A component can be mounted on the rear panel of the housing without a U-rail. Up to seven components can be mounted on a U-rail, depending on the size of the component.
  • Page 17: Laying The Cables And Connecting The Batteries

    Mounting Laying the cables and connecting the batteries 4.3 Laying the cables and connecting the batteries Primary wiring WARNING Electrical voltage Electric shock ● Before connecting the mains cable, make sure that the cable is current-free. ● Ensure that the mains is secured against inadvertently being switched on. Secondary wiring NOTICE Short-circuit...
  • Page 18 Mounting Laying the cables and connecting the batteries The following instructions must be observed. ● The cable cross section for each of the three lines of the mains cable is 1.5…2.5 mm ● The mains cable must be inserted from above on the left of the housing and must not be laid outside the boundary of the mains zone.
  • Page 19: Connecting The Signal Lines And Dc 24 V

    Mounting Laying the cables and connecting the batteries 4.3.1 Connecting the signal lines and DC 24 V Figure 2: x = cable tie The figure above shows the cable ties (x), which are also required for the mains lines, even though these are only connected after the signal lines. 5 mm Figure 3: Stripping the cables Max.
  • Page 20 The line for the 'Fault' signal transfer of the power supply is wired to a fire control panel, such as an FC120, for example. This connection is only permitted if the housings are mounted side by side. Otherwise, the connection must be monitored. AUX. 24V INPUT FP120-Z1 FC120 20 | 32 Building Technologies A6V10393194_d_en_-- Fire Safety...
  • Page 21: Connecting The Mains Cable

    Mounting Laying the cables and connecting the batteries 4.3.2 Connecting the mains cable 5 mm Outer insulation of the mains cable Cable tie w The mains cable is de-energized and the network is secured against inadvertently being switched on. 1. Feed the mains cable into the housing with the length required. 2.
  • Page 22: Installing And Connecting The Batteries

    Mounting Installing and connecting the batteries 4.4 Installing and connecting the batteries Cable bridge Cables, black (–) Cables, red (+) Connect suitable batteries, as shown, and connect the cable bridge (1). You will find suitable batteries in the 'Components / accessories / spare parts [➙...
  • Page 23: Switching The Mains Voltage To Ac 115 V

    230 V Output 70 W 115 V 115 V Control Code: XXYZWWW DO NOT OPEN COVER EN54-4 VdS: G 213083 0786-CPR-21302 Siemens Sw itzerland Ltd Country of Origin: China Akku Usys 23 | 32 A6V10393194_d_en_-- Building Technologies Fire Safety 2018-11-05...
  • Page 24: Battery Capacity

    Battery capacity 6 Battery capacity The required battery capacity depends on the required standby and alarm time, the aging factor, and the total current in the relevant mode. Observe the country-specific or EN regulations. The required battery capacity can be identified using the following table and the calculation formula.
  • Page 25: Checking Functions

    Checking functions 7 Checking functions The functions must be checked after installation and in accordance with the maintenance regulations. NOTICE Open line of the power supply for external devices Unwanted automatic service provider notification. ● For both function checks, ensure that the alternative power supply is active respectively.
  • Page 26: Maintenance

    Maintenance 8 Maintenance Comply with all local maintenance regulations and use the following maintenance recommendation. Depending on national regulations, the maintenance intervals can be set differently from the following maintenance recommendation. Maintenance recommendation Interval/year Check the display and transmission of a mains fault and a battery fault in the overall connected system.
  • Page 27: Faults / Troubleshooting

    Faults / Troubleshooting 9 Faults / Troubleshooting If a fault cannot be eliminated with the help of the following information, please contact the service engineer. Symbol Status LED Description Possible cause Measures System not operational ● With a voltage ● Check the mains voltage.
  • Page 28: Components / Accessories / Spare Parts

    Scope of delivery The power supply kit (70 W) is supplied mounted with housing, a left-hand installation frame with integrated power supply (70 W) FP2015 and FP120-Z1 mainboard, a right-hand installation frame for optional components, and a pre- wired connection for the battery, as well as mounting instructions for wall mounting and optional components: Document ID A6V10393173.
  • Page 29: Technical Data

    Charging current Max. 1.6 A, the charging current is reduced at full load Connectable batteries 2x 12 V / 7…17 Ah Battery types recommended by Siemens in accordance with 'Components / accessories / spare parts' chapter Battery internal resistance (R Max.
  • Page 30 Technical data Mechanical data Dimensions (W x H x D) 430 x 399 x 124 mm Weight 3,920 kg, without batteries Housing color ∼ RAL 9010 pure white Protection category (IEC 60529) IP 30 30 | 32 Building Technologies A6V10393194_d_en_-- Fire Safety 2018-11-05...
  • Page 31: Disposal

    Disposal 12 Disposal This equipment is manufactured using materials and procedures which comply with current environmental protection standards as best as possible. More specifically, the following measures have been undertaken: ● Use of reusable materials ● Use of halogen-free plastics ●...
  • Page 32 Issued by © Siemens Switzerland Ltd, 2014 Siemens Switzerland Ltd Technical specifications and availability subject to change without notice. Building Technologies Division International Headquarters Theilerstrasse 1a CH-6300 Zug +41 58 724 2424 www.siemens.com/buildingtechnologies Document ID: A6V10393194_d_en_-- Edition: 2018-11-05...