Digital fluid controller – single product

Advertisement

Fluid Solenoids are installed at each dispense point (Station). Use the instruction sheet included
with the Fluid Solenoid for correct installation. For reels, mount the Fluid Solenoid next to the reel
and connect the side hose to the fluid outlet of the Solenoid, for Oil Bars mount the Fluid
Solenoid above arms reach on the wall (to prevent intentional short circuiting by the end user
and possible system damage).
CAUTION: There are two different versions of the Fluid Solenoid, Model 1065 is for Oils (0-
3000PSI) and Model 1064 is for water base products - Windshield Wash Fluid and Anti Freeze (0-
250PSI).
Input Voltage/Amperage
Input Fuse
Output Voltage
Output Amps
Transformer Rating
Maximum Stations Controlled
Maximum Pre-Set Quantity
Minimum Pre-Set Quantity
Maximum Totalizer Value
Maximum Fluid Pressure (Oil)
Maximum Fluid Pressure (H20) Presión de fluido máxima (H20)
Minimum Flow
Maximum Flow
Symptoms
No Power.
DFC Ready Light OFF.
Station Ready Light OFF.
No Product flow at any Dispense Point.
DFC Ready Light ON.
Ready Light at Station OFF.
No Product flow at Dispense Point.
Samson Corporation-Swannanoa, NC 28778-
Technical Data/ Datos Técnicos
Voltaje/Amperaje De Entrada
Fusible De la Entrada
Voltaje De la Salida
Salida Amperios
Grado Del Transformador
Estaciones Máximas Controladas
El Máximo Preestableció Cantidad
El Mínimo Preestableció Cantidad
Valor Máximo Del Totalizador
Presión de fluido máxima (Aceite)
Flujo Mínimo
Flujo Máximo

Troubleshooting

Possible Reasons
120VAC Power input cord unplugged.
Main Circuit Breaker Tripped at building
Panel.
External Fuse on back of DFC Blown.
Dispense not Authorized.
DFC Defective.
Station Selector in wrong position.
Output Fuse Blown.
Station wires connected incorrectly.
Station wires defective, shorted or
grounded internally and/or externally.
Station
wires
defective,
internally or disconnected.
Ready Light defective.
Ready Light and Fluid Solenoid wired in
Series Circuit.
800.311.1047 www.samsoncorporation.com
120 VAC/10AMPS (minimum)
2.25 Amps
24VAC
2.25 Amps (fused)
40VA
10
99999.9 Units
.1 Units
9999999.9 Units (Rolls over to Zero
– not externally resettable)
180 bar (3000 PSI)
15 bar (250 PSI)
1 l/min (¼GPM)
26 l/min (6 GPM)
Solutions
Plug the Power Cord into a properly
grounded outlet.
Unplug the DFC console and find the
cause of the fault and rectify before
resetting Circuit Breaker.
Find the cause of the fault and rectify
before replacing the fuse.
Authorize
a
dispense
Operation section of this manual.
Replace DFC.
Rotate the switch to the correct Station.
Find the cause of the fault and rectify
before replacing the fuse.
Trace wire routing and connections and
repair.
Trace and Repair.
broken
Trace and Repair.
Test for continuity and Repair.
Rewire in Parallel Circuit.
using
the
1060
5