Samson 1060 Parts And Technical Service Manual
Samson 1060 Parts And Technical Service Manual

Samson 1060 Parts And Technical Service Manual

Digital fluid controller – single product

Advertisement

Quick Links

1060 DIGITAL FLUID CONTROLLER – SINGLE PRODUCT
1060 REGULADOR DEL LÍQUIDO DE DIGITAL - SOLO PRODUCTO
1060 CONTRÔLEUR DE FLUIDE DE DIGITAL - PRODUIT SIMPLE
Parts and Technical Service guide
Guía de servicio técnico y recambio
Guide d'instructions et pièces de rechange
E
Low
Voltage
(24VAC)
Controller for Single product usage. The
DFC Inventory Control System is designed
for use as a central positive control of a
variety of fluids such as Motor Oil, Gear
Oil, and ATF. Includes both a pre-set
counter and a non-resettable totalizer.
This unit is capable of dispensing pre-set
amounts of fluid to any one of the ten
available stations.
SP
Regulador flúido Digital de la baja tensión
(24VAC) para el solo uso del producto. El
sistema de control de inventario de DFC
se diseña para el uso como un control
positivo central de una variedad de líquidos tales como aceite del motor, aceite del engranaje, y ATF. Incluyes
un contador preestablecido y un totalizador no-restaurable. Esta unidad es capaz de dispensar c
p
reestablecidas de líquido de las diez estaciones disponibles.
F R
Contrôleur liquide de Numérique de la basse tension (24VAC) pour l'utilisation simple de produit. Le système
de vérification de l'inventaire de DFC est conçu pour l'usage comme une commande positive centrale d'une
variété de fluides tels que l'huile de moteur, l'huile de vitesse, et ATF. Incluses un compteur préréglé et un
totalisateur non-réglable. Cette unité
q
uel un des dix stations disponibles.
E
Determine the amount of product to be dispensed.
Press and hold the 'PRESET ACTUATOR' button located in the lower left corner of the face of the unit.
While continuing to hold the 'PRESET ACTUATOR' button use the numbered buttons located u
preset display to enter the amount desired. Button #1 is tenths, #2 is ones, #3 is tens, etc.
When the correct am
ACTUATOR' button.
Rotate the 'STATION SELECTOR' knob to the desired station.
Simultaneously depress the 'PRESET ACTUATOR' button and the 'RST' button (RST
lower left corner on the face of the preset display) to energize the selected station.
The DFC ready light (located above the totalizing counter) will illuminate, the uppe
preset display will reset to 0.0, and the selected station is ready to dispense product.
The pre-set meter counts UP as the product is dispensed. When the pre-set amount has been
dispensed, the ready light will e
for the next dispense operation.
If the technician does not take the entire authorized dispense, the ready li
unit can still be reset for the next dispense following the above procedure
This unit will accept a preset of 0.0 but this will not cancel the dispense.
Samson Corporation-Swannanoa, NC 28778-
Description/ Descripción/ Description
Digital
Fluid
est capable de distribuer des quantités préréglées de fluide à n'importe
Operation/ Modo de empleo/ Mode d'emploi
ount is shown on the bottom section of the preset display, release the 'PRESET
xtinguish and the solenoid at the station will close. The unit is ready
Ref.: 1060
ght will not extinguish. The
.
800.311.1047 www.samsoncorporation.com
Single Product DFC
24VAC System
antidades
nder the
is located at the
r section of the
1060
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1060 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Samson 1060

  • Page 1 1060 DIGITAL FLUID CONTROLLER – SINGLE PRODUCT 1060 REGULADOR DEL LÍQUIDO DE DIGITAL - SOLO PRODUCTO 1060 CONTRÔLEUR DE FLUIDE DE DIGITAL - PRODUIT SIMPLE Parts and Technical Service guide Ref.: 1060 Guía de servicio técnico y recambio Single Product DFC Guide d’instructions et pièces de rechange...
  • Page 2 Si le technicien ne prend pas l'entier autorisé distribuez, la lumière prête ne s'éteindra p as. L'unité peut encore être remise à zéro pour le prochain distribuent après le procédé ci-dessus. • Cette unité n'acceptera pas a préréglé de 0,0. 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...
  • Page 3 Up to Ten Up to Twelve 18-Stranded 8468 400 Feet 16-Stranded 8620 600 Feet Up to Two Up to Four 16-Stranded 8621 600 Feet Up to Seven Up to Nine 16-Stranded 8622 600 Feet 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...
  • Page 4 Y-Strainers are located at each dispense point (Station) immediately upstream of the Fluid Solenoid. Use the instruction sheet included with the Model 1069 Y-Strainer for correct installation. 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...
  • Page 5 Station wires defective, broken Trace and Repair. internally or disconnected. Ready Light defective. Test for continuity and Repair. Ready Light and Fluid Solenoid wired in Rewire in Parallel Circuit. Series Circuit. 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...
  • Page 6 Impulse Meter micro-switch out of Readjust and test. adjustment – double clicking. Air leaks in Pump suction. Reseal Pump suction tube. Foot valve on Pump missing, not sealed Replace, Reseal, or Repair. or defective. 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...
  • Page 7 DFC Console defective. Not likely – see the special diagnostic procedures below. If defective replace. The Fluid Solenoid is hot. Normal Condition. Samson Fluid Solenoids are rated for a 110% duty cycle – this means that they remain energized indefinitely...
  • Page 8 An improperly sealed suction tube causes this problem with quite a bit of frequency, and generally shows up as ‘spitting’ or foaming at the Dispense Point (Station). 1060 Samson Corporation-Swannanoa, NC 28778- 800.311.1047 www.samsoncorporation.com...

Table of Contents