Manual Adjustments With A Remote Control - Chamberlain RSW12UL Installation Manual

Residential dc vehicular swing gate operator
Hide thumbs Also See for RSW12UL:
Table of Contents

Advertisement

To reduce the risk of INJURY keep clear of moving arm while setting limits.

Manual Adjustments with a Remote Control

To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer to
the Programming section.
Enter Manual Setup Mode
NOTE: For dual gate applications the limits will have to be set for
each operator. The gate MUST be attached to the operator before
setting the limits and force.
NOTE: While setting the Limits, all entrapment protection devices
will be disconnected, and the Remote Control buttons can be used to
move the gate as needed. During the Automatic Force Setup, all
entrapment protection devices will be reconnected, and the gate will
automatically open and close.
Ensure the gate is closed.
1. To enter manual set up mode, make sure that both SET OPEN and
SET CLOSE LEDs are flashing. If they are not flashing, press and
release both the SET OPEN and SET CLOSE buttons.
Reversal Force Dial
2.
The REVERSAL FORCE DIAL is set to minimum at the factory. You
will be able to adjust the force setting after the initial Manual Setup.
Once initial limits have been set, the REVERSAL FORCE dial on the
Control Board is used to fine tune the force where wind or
environmental changes may affect the gate travel.
Settings 1-10: Automatically increase the force due to gate wear or
temperature changes.
Set the Limits
3.
Press and hold the OPEN or CLOSE button on the remote control
until the gate reaches the desired open position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
4.
Once the gate is in the desired open position, press and release the
STOP button on the remote control.
5.
Press and release the OPEN button on the remote control again to
set the open limit.
6.
Press and hold the CLOSE or OPEN button on the remote control
until the gate reaches the desired close position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
7.
Once the gate is in the desired close position, press and release the
STOP button on the remote control.
APPENDIX
8.
Press and release the CLOSE button on the remote control again to set
the close limit.
9.
Upon successfully setting Limits for your gate setup, the manual
setup mode will exit.
Refer to the Adjustment section and follow the instructions for Fine Tune
the Force and Obstruction Test. Perform the "Obstruction Test" after
every limit and force setting adjustment.
Adjust the limits
If the limits have already been set the operator will exit the Manual Setup
Mode after resetting each limit.
Set the Close Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter Manual Setup Mode.
2. Press and hold the CLOSE button on the remote control until the gate
reaches the desired close position. The gate can be jogged back and
forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
4. Press and release the CLOSE button on the remote control again to set
the close limit.
When the close limit is set properly the operator will automatically exit
Manual Setup Mode and enter Automatic Force Setup Mode.
Set the Open Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter Manual Setup Mode.
2. Press and hold the OPEN button on the remote control until the gate
reaches the desired open position. The gate can be jogged back and
forth using the OPEN and CLOSE buttons on the remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to set
the open limit.
When the open limit is set properly the operator will automatically exit
Manual Setup Mode and enter Automatic Force Setup Mode.
3-Button Remote Control programmed for OPEN, CLOSE, and STOP