LIMIT SETUP WITH A REMOTE CONTROL

To set the limits using a remote control, first you will need a 3-button remote control that has been programmed for OPEN, CLOSE, and STOP. Refer
to the Programming section.
INITIAL LIMITS AND FORCE ADJUSTMENT
For dual gate applications the limits will have to be set for each
operator. The gate MUST be attached to the operator before setting the
limits and force.
Ensure the gate is closed.
1. Press and release the SET OPEN and SET CLOSE buttons
simultaneously to enter limit setting mode.
2. Press and hold the OPEN or CLOSE button on the remote control
until the gate reaches the desired open position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
3. Once the gate is in the desired open position, press and release the
STOP button on the remote control.
4. Press and release the OPEN button on the remote control again to
set the open limit.
5. Press and hold the CLOSE or OPEN button on the remote control
until the gate reaches the desired close position. The gate can be
jogged back and forth using the OPEN and CLOSE buttons on the
remote control.
6. Once the gate is in the desired close position, press and release the
STOP button on the remote control.
7. Press and release the CLOSE button on the remote control again to
set the close limit.
8. Cycle the gate open and close. This automatically sets the force.
When limits are set properly the operator will automatically exit limit
setting mode.
APPENDIX
ADJUST THE LIMITS
If the limits have already been set the operator will exit the limit setting
mode after resetting each limit.
Set the Close Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
2. Press and hold the CLOSE button on the remote control until the
3. Once the gate is in the desired close position, press and release the
4. Press and release the CLOSE button on the remote control again to
When the close limit is set properly the operator will automatically exit
limit setting mode.
Set the Open Limit Only
1. Press and release the SET OPEN and SET CLOSE buttons
2. Press and hold the OPEN button on the remote control until the gate
3. Once the gate is in the desired open position, press and release the
4. Press and release the OPEN button on the remote control again to
When the open limit is set properly the operator will automatically exit
limit setting mode.
3-Button Remote Control programmed for OPEN, CLOSE, and STOP
DIAGNOSTICS
DIAG
50
simultaneously to enter limit setting mode.
gate reaches the desired close position. The gate can be jogged back
and forth using the OPEN and CLOSE buttons on the remote control.
STOP button on the remote control.
set the close limit.
simultaneously to enter limit setting mode.
reaches the desired open position. The gate can be jogged back and
forth using the OPEN and CLOSE buttons on the remote control.
STOP button on the remote control.
set the open limit.