Advertisement

Quick Links

Ambience
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Drive Ambience and is the answer not in the manual?

Questions and answers

Summary of Contents for DeVilbiss Healthcare Drive Ambience

  • Page 1 Ambience User Manual...
  • Page 2: Table Of Contents

    Contents Fire Warning Safe Guards Introduction Product description Intended use Contraindication Installation Unpacking Setting up Product functions Audible and Visual Alarm Power Failure Alarm Cleaning Pump Mattress Maintenance Storage Troubleshooting Technical Description Electromagnetic Interference Warranty...
  • Page 3: Fire Warning

    Fire Warning This active mattress system complies with all UK fire safety standards. In order to reduce the risk of fire: DO NOT SMOKE - Smoking will contaminate the product and is NOT permitted around or on the mattress system. This is a common cause of fatal fires.
  • Page 4: Safe Guards

    Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped in water, return the product to Drive DeVilbiss Healthcare for examination and repair.
  • Page 5: Introduction

    Introduction This manual should be used for initial setup of the system and for reference purposes. Product Description True Low Air Loss therapy is achieved through a high volume airflow blower and numerous air loss holes in the mattress. It also provides excellent ventilation and keeps patients dry from humidity.
  • Page 6: Installation

    The pump unit and mattress are packaged separately to secure the contents inside. When unpacking to remove the pump unit and mattress, check for any damage which may have occurred during transit. Please report any damages to Drive DeVilbiss Healthcare as soon as practicable and remove the system from use. Setting Up Place the mattress on top of the bed frame.
  • Page 7: Product Functions

    Product function Function Description Power standby The control panel automatically locks after 3 minutes of inactivity to prevent unauthorised setting changes. To unlock the panel, press and the button for 5 seconds. Provides a firm support surface for a healthcare professional to work on Users can adjust the pressure of air mattress by adjusting the comfort range from level 1 to 10.
  • Page 8: Cleaning

    Cleaning The following guidelines are suggested by Drive DeVilbiss Healthcare as being suitable infection control procedures. Further information is available upon request. Pump Unit General cleaning may be affected by using a cloth dampened with a mild detergent and water solution. This approach may be followed either by wiping with a sodium hypochlorite solution to a dilution of 1000 ppm or by using an alcoholic wipe.
  • Page 9: Maintenance

    Ensure the main power cord and plug is free from abrasions and/or excessive wear. Replace if damaged Check the mattress cover for signs of wear and damage. Replace is there are any signs of fluid ingress Replacement parts can be purchased from Drive DeVilbiss Healthcare Storage Disconnect the automatic fowler boost adaptor on the side of the pump unit.
  • Page 10: Troubleshooting

    Large airflow from air This is normal as the system has a high airflow and numerous air loss holes in all bladders bladder/air cells. If your problem cannot be resolved using the above information, please contact Drive DeVilbiss Healthcare...
  • Page 11: Technical Description

    200cm x 90cm x 20.3 (25.4) cm Weight 13 kg Maximum Patient Weight 180 kg / 28.3 stones Please contact Drive DeVilbiss Healthcare for further technical information. The specification is also suitable for other areas operating with the same power supply. NOTE: Electromagnetic Interference •...
  • Page 12: Warranty

    Warranty Your Drive DeVilbiss Healthcare product is warranted to be free of defects in materials and workmanship for one year from date of purchase. This device was built to exacting standards and carefully inspected prior to shipment. This warranty is an expression of our confidence in the materials and workmanship of our products and our assurance to the customer.
  • Page 13 Our goal is to develop a range that will provide individuals with a chance to enjoy everyday life. Leaflet code: 6002990021 Dealer Stamp Drive DeVilbiss Healthcare Ltd, Heathfield Lane, Birkenshaw, West Yorkshire, BD11 2HW Tel: 0845 0600 333 Fax: 0845 0600 334 Email: info@drivedevilbiss.co.uk...

This manual is also suitable for:

1001020001

Table of Contents