58 Parameters
No.
Name/Value/Range

149 Control unit communication

149.01
Control unit node ID
1 ... 32
149.03
Control unit baud rate
Reserved
38.4 kbps
57.6 kbps
86.4 kbps
115.2 kbps
230.4 kbps
149.06
Refresh settings
Done
Configure
149.20
Terminal X1, X8
Control unit
Modbus RTU
Control unit#2
149.21
Terminal X2
Modbus RTU
Control unit
Description
Unique node identification in the communication
network.
Maximum communication baud rate for the
inverter. Reliability of the communication may
require lower setting, depending on the electrical
characteristics of the wiring.
-
38.4 kbps
57.6 kbps
86.4 kbps
115.2 kbps
230.4 kbps
Applies settings from parameters 149.01, 149.03,
149.20, 149.21,
149.23
Note: Changing the settings will cause a
communication break. The control unit
reconnects automatically, but other bus masters
may need to be reconnected manually.
Refresh done.
Refresh parameters
149.01
value reverts automatically to Done.
Shows currently active protocol on terminals X1
and X8.
Note: Terminals X1 and X8 are internally
connected and share the same UART.
Terminal X1 is intended for connecting the
remote PVS-AP-L control unit.
This parameter is read only.
Selects the active protocol on terminal X2.
Swaps the protocols such that the protocol on
terminal X2 moves to terminals X1 and X8, and
the control unit protocol becomes active on
terminal X2.
Note:
• This is a volatile setting, meaning, the setting
reverts back to the control unit protocol on
terminals X1 and X8 whenever the inverter is
power cycled.
• Enabling the control unit protocol on
terminal X2 also enables firmware update over
terminal X2.
and 149.24.
and 149.03. The
Default
FbEq (16b/32b)
2
1 = 1
115.2 kbps
0
1
2
3
4
5
Done
0
1
Control unit
0
1
2
Modbus RTU
0
1